Heater cannot be
turned off
Cabinet heaters must always be turned OFF by closing
the gas cylinder valve (clockwise ). Note that it may be
in the fully open position and will require some effort to
start the closing operation.
Heater will not
remain alight when
the ignition button is
released
The Oxygen Depletion Sensor solenoid is not keeping
the control open. Have the heater serviced by an
authorised service agent.
Should this happen after storage, the components may
require cleaning.
TECHNICAL DATA
Brand
Model
Rated Gas Consumption
Rated Power
Russell
Hobbs
RHG03
1 panel (ghr
-1
)
103
1 panel (W)
1 400
Operating Pressure
2 panel (ghr
-1
)
206
2 panel (W)
2 800
2.8 kPa
3 panel (ghr
-1
)
310
3 panel (W)
4 200
Electric Heater
Element 1
1000W 230V
Element 2
1000W 203V
CHANGING THE PLUG
Should the need arise to change the fitted plug, follow the instructions below.
This unit is designed to operate on 230V current only. Connecting to other power
sources may damage the appliance. Connect a three-pin plug as follows:
The wires in this mains lead are coloured in
accordance with the following code:
Green/Yellow = Earth
Blue
= Neutral
Brown
= Live