![Russell Hobbs RHDW1 Service Manual Download Page 62](http://html1.mh-extra.com/html/russell-hobbs/rhdw1/rhdw1_service-manual_1500893062.webp)
R
E
D
R
E
D
NTC SENSOR:
From the electronical card:
CN 3.1 - CN 3.2
25°-5000
Ω
-%±5.0
35°-3300
Ω
-%±5.5
55°-1520
Ω
-%±6.5
63°-1174
Ω
-%±7.5
80°- 670
Ω
-%±8.0
90°- 488
Ω
-%±8.5
.
Above sketch show the connectors of NTC sensor on the electronical card. Probes of
the tester should be applied on to the related connectors.
From the component:
Probes of the tester should be applied on to the related connectors as shown on the
pictures
Diverter :
From the electronical card :
CN6.1 – CN 2.9
6840
Ω
-%±5.0
Sketch at the side show the connectors of
the diverter on the electronical card.
Probes of the tester should be applied on
to the related connectors.
ELECTRON
İ
CAL CARD
CONNECTOR
EECTRON
İ
CAL CARD
CONNECTOR
B
L
A
C
K
CONNECTORS SHOULD BE MEASURED
W
H
IT
E
R
E
D
CONNECTORS SHOULD BE MEASURED
59