5
INSTALLATION
Warning:
-
The machine has to be set in a dry and well-ventilated place, where the air is changed at a
minimum of once an hour; fresh air content (without equipment supporting ventilation) -
50%.
-
Temperature in the place of work: 10-35
°°°°
C, humidity: 50-90%.
-
The surface, on which the machine stands, may be inclined at no more than 5-10 degrees.
CONNECTION TO POWER SUPPLY NETWORK
Before connecting the power supply cable make sure that the switch is in the OFF (0) position. Connect the
machine to a socket, which is able to withstand the machine load.
CONNECTION OF TOOLS (S135E)
Insert the plug into the socket (5) (Fig. 2); if the tool is equipped with a dust extraction system, connect it via
the suction hose with the coupling (Fig. 3 and 4).
PRELIMINARY CHECK
As soon as you connect all the elements, check if:
-
The dust bag (7) is inside the container (9);
-
the suction hose is securely connected.
OPERATION OF DUST EXTRACTION MACHINE
The machine may be used in manual or automatic operation mode.
MANUAL OPERATION
1. Set switch (3) in the ON position (I).
2. Set switch (4) in the ON position (MAN) (only S135E).
In this setting the machine works continuously, independent of whether the tool is working or not.
AUTOMATIC OPERATION (only S135E)
Set switch (3) in the ON position (I) and switch (4) in the automatic mode (AUT).
In this setting the extraction proceeds only while the connected tool is working . As soon as the tool is
switched of, suction will automatically stop.
MANUAL OPERATION FOR EXTRACTION OF LIQUIDS
1. Release hooks (12) fastening the machine head (1) (Fig. 5).
2. Remove filter element (14) (Fig. 7-8) and dust bag (7) (Fig. 10).
3. Insert polyester filter (15) into suction basket (Fig. 9) and fasten the hooks again.
4. Set switch (3) and switch (4) (only S135E) in manual mode (MAN).
GUIDELINES
Do not connect loads exceeding the amount permissible.
First check if all the operations have been completed according to the guidelines provided above, and then
test the working of the tools in compliance with their respective operating instructions.