least four inches of excelsior or similar shock-absorbing material. 

CLAIM FOR DAMAGE IN SHIPMENT 

TO ORIGINAL PURCHASER 

The instrument should be thoroughly inspected immediately upon original delivery to purchaser. All material in the 

container should be checked against the enclosed packing list. The manufacturer will not be responsible for shortages 

against the packing sheet unless notified immediately.   

If  the  instrument  is  damaged  in  any  way,  a  claim  should  be  filed  with  the  carrier  immediately.  (To  obtain  a 

quotation to repair shipment damage, contact the nearest Service Center.) Final claim and negotiations with the carrier 

must be completed by the customer. 

 

 
 
 
 
 
 
 
 
 
 

Summary of Contents for 01+

Page 1: ...www victorruoshui co kr 이 자료는 저작권법에 따라 보호받는 저작물이므로 무단배포 및 무단복제를 금하며 내용을 이용하려면 한국 VictorRuoshui 社 의 서면동의를 받아야 합니다 TEMPERATURE CALIBRATOR OPERATION MANUAL RuoShui 01 ...

Page 2: ...on and explanations of the features To avoid possible electric shock or any other dangers please do follow the under mentioned rules Warning Do not operate the meter around explosive gas vapor or dust which is extreme dangerous Never apply voltage exceeding 30V between any two terminals and earth ground terminals Caution Do not open the meter s case except for the professional technicians Use a da...

Page 3: ... zero point or full point etc when the meter is in calibration state d RJ ON indicates the meter has undergone cold junction compensation See Section 5 2 e indicates the batteries are exhausting and needs replacement See Section 3 2 f indicates present set output value g mV C indicates the unit for present output value LCD display part power on shift thermocou ple cold compensat ion range selectio...

Page 4: ...n the meter off and remove all test leads 2 Shake out any dirt that may be in terminals 3 Soak a new swab with alcohol Clean each terminal with the swab 2 Replacing the batteries The meter is powered by two LR6 alkaline batteries AA Warning To avoid electrical shock or personal injury Remove test leads from the meter before opening the battery door Close and latch the battery door before using the...

Page 5: ...er The default factory value is set as the meter will automatically turn off if no operation has been made within 15 minutes The Users can set by themselves to choose whether using this function or not See Section Six Section Five Output of the Meter The meter generates DC current or simulate resistance set by the Users from the corresponding output terminals OUTPUT Caution Do not apply any voltag...

Page 6: ...ne second 6 Automatic compensation of cold junctions When calibrating meter with temperature cold junction compensation directly press RJ ON key to start the automatic compensation function of cold junctions of this meter and it will output the necessary temperature thermoelectric force and display RJ ON See Section Seven for the accuracy of cold junction compensation and Output thermoelectric for...

Page 7: ...ng the correct simulate output of 400Ω the incentive current should be within 0 5 3mA range for simulate output of 4000Ω the incentive current should be within 0 05 0 3mA range Note Resistance simulate when the output resistance is 4 wired for calibration the error generated by the resistance approximately 0 1 of test lead should be considered if the Users employ two wires connection method The me...

Page 8: ...f state press power key and the LCD displays in full loose power key and press RANG key the meter enters into maintenance state and the LCD displays AP XX 2 Press key and the LCD displays symbol AP OF the meter stops automatically power off function The LCD displays symbol AP ON the meter restores automatically power off function and the meter exit from maintenance state if cutting off the power a...

Page 9: ... 05 1 C 100 C K 200 0 1370 C 0 1 C J 200 0 1200 0 C 0 1 C T 200 0 400 0 C 0 1 C N 200 0 1300 0 C 0 1 C RTD Cu10 10 0 C 250 0 C 0 1 C 0 05 0 6 C incentive current 0 5 3 mA when the incentive current is 0 1 0 5 mA add 0 5 C additional error Cu50 50 0 C 150 0 C 0 1 C 0 05 0 6 C Pt10 385 200 0 C 850 0 C 0 1 C 0 05 0 6 C Pt100 385 200 0 C 850 0 C 0 1 C 0 05 0 6 C Pt200 385 200 C 630 C 0 1 C 0 05 0 6 C ...

Page 10: ...ensation is less than or equals to 0 5 C General Feature power 2 1 5V alkaline batteries LR6 power consumption about 60m 3V maximum allowed voltage 30V within terminals or between terminal and earth ground operation temperature range 0 C 50 C operation humidity range 80 RH storage temperature range 10 C 55 C storage humidity range 90 RH temperature coefficient 0 1x dedicated accuracy C 5 C 18 C 28...

Page 11: ...e operation instruction is regarded as correct Whenever any user finds its mistakes omission etc he or she is requested to contact the manufacturer The present manufacturer is not liable for any accident and hazard arising from the customer misuse or inadvertent operation The functions described in this operation instruction should not be used as grounds to apply this product to a particular purpo...

Page 12: ...id to the nearest Service Center Our company assumes no risk for the damage in transit Our company will at its option repair or replace the defective product free of charge or refund your purchase price However if our company determines that the failure was caused by misuse alterations accident or abnormal condition of operation or handing you will be billed for the repair and the repaired product...

Page 13: ...ely upon original delivery to purchaser All material in the container should be checked against the enclosed packing list The manufacturer will not be responsible for shortages against the packing sheet unless notified immediately If the instrument is damaged in any way a claim should be filed with the carrier immediately To obtain a quotation to repair shipment damage contact the nearest Service ...