4
2. Press
to finish adjustment, press
to return.
Signal Output
Mode
1. Under the Signal Output Mode display status, Press
enter into program set mode. Signal output mode value
flashes, press
or
to adjust the value.
2. Press
to finish adjustment, press
to return.
For example, a softener has set fast rinse time as 12 minutes. After
regenerating, the chloridion in the outlet water is always higher than normal,
which indicate that fast rinse time is too short. If you want to set the time as
15 minutes, the modification steps as follows:
①
Press and hold both
and
to unlock the button (The fourth
decimal point of digital tube lights off);
②
Press
, the third decimal point of digital tube lights on;
③
Press
or
continuously until in fast rinse status, the digital
display area shows: 5-12M
④
Press
, 12 flashes
⑤
Press the
continuously, until 12 change
s
to 15
⑥
Press
again and hear a sound "Di", the frame stop flickering, the
program returns to inquiry status;
⑦
If you want to adjust other parameters, you need to adjust as above
3-5 steps; if not, press
to exit the program inquiry status and the screen
displays the current working status.