RUNHOOD HE600-B User Manual Download Page 3

PRODUCT SAFETY GUIDELINES 

BEFORE STARTING

Please carefully read all instructions before using RUNHOOD Portable Power Station.

WARNING

 Keep RUNHOOD Power Station dry and do not expose to high heat or water.
DO NOT disassemble or remove the protective covering.
DO NOT puncture or incinerate the product or the accessories. 
Recycle and dispose of RUNHOOD Power Station in accordance with the local regulations.
Pay attention to safety when handling the RUNHOOD Power Station.
Children and those with impairments should operate the device with assistance. 
Improper use may result in fire, property damage or personal injury.
Only use the product according to the safety guidelines.

PRODUCT USE

DO NOT expose RUNHOOD Power Station to liquid or to rain, snow, hail, etc. 

DO NOT pierce the product. Doing so may cause leakage or fire hazard. 
 DO NOT use the product if it is involved in a crash or a heavy impact. 

DO NOT put the device inside a microwave oven or a pressurized container. 

1

DO NOT submerge the RUNHOOD Power Station in water. Exposure to water may cause chemical 

decomposition of the battery resulting in combustion. Please contact our service department for 

assistance on such occasions. 
Only use RUNHOOD batteries with this product. RUNHOOD takes no responsibility for any damage caused by 

non- RUNHOOD Power Station batteries. 
The

 

discharging

 

temperature

 

of

 

Energy

 

Bar

 

324

 

is

 

-68~113°F/-20~45°C, while

 

the

 

charging temperature

 

is

 

32~104°F/0~40°C. Failure to do so may result in hazard, permanent damage, or reduced performance.

This product is recommended to be used at 68~77℉/20~25℃, otherwise, the higher the temperature, the 

shorter the working time may be.

Using the batteries in a strong electrostatic or electromagnetic environment may cause the battery control board 

to malfunction and cause serious hazard during use.

If the product is submerged in water during use, remove the product immediately and leave it in a safe and open area. Keep 

a safe distance until it is completely dry and dispose of it as described in the Battery Disposal section below. All components 

and modules of the power station previously submerged in water should not be used again under any circumstance.

 If the product catches fire, it is recommended to use fire extinguishing equipment in the following order: water, 

sand, fire blanket, dry powder, carbon dioxide fire extinguisher. 

DO NOT insert pins, wires, or other metals into the device case, outlets, or controls. Doing this may short circuit 

the product. 

Avoid collision. 

Summary of Contents for HE600-B

Page 1: ...230V 50Hz...

Page 2: ...6 UE256 ENERGY BAR 324 EB324 ACCESSORIES DIY COMBINATIONS 648Wh 600W HE600 B 1 EB324 2 324Wh 80W AE80 B EB324 324Wh 256W UE256 EB324 RECHARGE METHODS INSTRUCTIONS OF RECHARGING EB324 THROUGH HE600 B I...

Page 3: ...partment for assistance on such occasions Only use RUNHOOD batteries with this product RUNHOOD takes no responsibility for any damage caused by non RUNHOOD Power Station batteries The discharging temp...

Page 4: ...ground with no flammable or combustible materials around To prevent accidents never leave the device unattended during charging DO NOT charge immediately after a long period of use for a high power a...

Page 5: ...AR CHARGER SOLAR CHARGER AC ON OFF DC ON OFF USB C PD 100W INPUT OUTPUT CAR PORT USB A QC3 0 2 DC OUTPUT 2 USB C PD 100W OUTPUT 230V AC OUTLET 2 LCD DISPLAY 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 1...

Page 6: ...er station is protected When AC and OVERLOAD icons flash together with warning buzzer please press AC ON OFF button to reset Press the DC ON OFF button to turn on or off the RUNHOOD Power Station DC o...

Page 7: ...ces including laptops tablets smart phones and other devices with a USB C port Two output outlets for 230V AC of Pure Sine Wave are designed to provide power to your appliances with a maximum rated po...

Page 8: ...ature warning icon appeared on the screen is to warn that the temperature of the HE600 B is too low DO NOT charge or discharge under such circumstance since the system may don t permit Please place th...

Page 9: ...ress DC ON OFF button to reset AC and OVERLOAD icons flash together with warning buzzer Press AC ON OFF button to reset High temperature icon with a warning buzzer means the batteries have overheated...

Page 10: ...cally If the device does not reset please contact our product specialists at service runhood power com When this icon is displayed there is a major failure Check for strong static or a magnetic field...

Page 11: ...in 600W The system has a buzzer notification which includes Low power alarm When power is less than 5 the buzzer sounds periodically The buzzer output can be turned off through the power switch or rec...

Page 12: ...Fast Recharge 1 AC Output Pure Sine Wave 230V 50Hz total 600W peak 1200W max AC Output 600W 68 113 F 20 45 C Discharging Temperature 32 104 F 0 40 C Charging Temperature 2 USB C PD 100Wmax 5V DC 3A 9V...

Page 13: ...erature 68 113 F 20 45 C AE80 B SPECIFICATION 11 2 WORKING STATUS INDICATOR White indicator normal output 230V Red indicator abnormal fail to output 230V AC OUTLET WORKING STATUS INDICATOR Supports ap...

Page 14: ...devices with USB C ports 12 2 USB A FAST CHARGE OUTPUT 28W 2 USB A can charge devices including smart phones tablets speakers and any other devices with USB A ports 3 USB C PD 100W OUTPUT Output USB C...

Page 15: ...D 100Wmax 5V DC 3A 9V DC3A 15V DC 3A 20V DC 5A total 200W max 2 USB A QC3 0 28W max 5V DC 3A 9V DC 3A 12V DC 2 4A total 56W max 13 POWER INDICATOR ON OFF SWITCH 1 POWER INDICATOR Each indicator repres...

Page 16: ...lbs 1 77 kg approx Dimension 10 2 2 3 4 1 in 26 5 7 10 3 cm Capacity 324Wh Battery Li ion NMC Discharging Temperature 68 113 F 20 45 C Charging Temperature 32 104 F 0 40 C Cycle Life 1000 times 80 E...

Page 17: ...DC Y CABLE Notice with DC 6530 port SOLAR PANEL Notice highly recommended RUNHOOD s Seri 100W with 15V 23V 15 SOLAR CHAGRING CABLE MC4 DC 6530...

Page 18: ...00W HE600 B 1 EB324 2 This is a power station of 648Wh 600W It is highly portable with a weight of only 16 lbs The design of swappable battery provides virtually unlimited durability With an extra pai...

Page 19: ...17 MINI POWER STATION of 324Wh to provide an AC output of 80W 324Wh 80W AE80 B EB324 SUPERPOWER BANK of a capacity of 324Wh with 2 USB C PD 100W outputs and 2 USB A QC 28W outputs has a maximum total...

Page 20: ...e two ways to recharge the EB324 one with HE600 B and the other with UE256 You need to combine the EB324 with HE600 B or UE256 for recharging the EB324 We highly recommend to recharge your EB324 in pa...

Page 21: ...ect the recharge cable to the USB C PD 100W IN OUT port to recharge 3 When charging DO NOT remove the EB324 from UE256 4 The USB C recharge cable and adapter are not included in our product range User...

Page 22: ...product must be brought to an electric and electronic waste collection point for recycling and disposal 1 The DC input of HE600 B can reach 200W max You can use a maximum of two RUNHOOD Solar Panels t...

Reviews: