Controls and Functions
6
Runco LS-7 Installation/Operation Manual
PRE
L
IMINAR
Y
•
POWER BUTTON/STATUS LED
Indicates projector status as follows:
• Solid green = AC power present, ready to turn on (lamp not lit)
• Flashing green = lamp is warming up or cooling down; keypad functions not allowed
• Off = Lamp lit, projector functioning normally
• Alternating green/red = Lamp problem (door open, unable to strike, end of life), user
intervention likely to fix problem
• Flashing red = Over temperature, user intervention (clear vents, turn on AC) may fix
problem
• Solid red = Error that requires servicing (fan fail, Power-on self-test fail etc.)
•
EXHAUST VENT
Warm air exits the projector through this vent. Ensure that it is not blocked.
•
INTAKE VENT
Internal fans draw cool air into the projector through this vent.
•
PROJECTION LENS
The inside of the lens barrel is threaded to accommodate a standard, 72-mm lens filter.
For example, with a smaller screen you can install a neutral-density filter to reduce the
overall light output.
If needed, a light shield accessory is provided with the lens to minimize stray light
emissions. (Use it only when the vertical offset is 50% of the screen height or greater.)
The light shield attaches to the end of the lens (or to the filter, if used).
•
FRONT IR SENSOR
Receives infrared signals from the remote control unit.
Summary of Contents for LIGHTSTYLE LS-7
Page 1: ...LS 7 Home Theater Projector INSTALLATION OPERATION MANUAL ...
Page 2: ......
Page 10: ...x Runco LS 7 Installation Operation Manual P R E L I M I N A R Y Notes ...
Page 14: ...Table of Contents xiv Runco LS 7 Installation Operation Manual P R E L I M I N A R Y Notes ...
Page 16: ...List of Figures xvi Runco LS 7 Installation Operation Manual P R E L I M I N A R Y Notes ...
Page 20: ...Introduction 4 Runco LS 7 Installation Operation Manual P R E L I M I N A R Y Notes ...
Page 46: ...Installation 30 Runco LS 7 Installation Operation Manual P R E L I M I N A R Y Notes ...
Page 99: ......