7-5
Service Mode
Memory management
Highlight
‘Memory management’
by pushing the control disc up or down and
press
ENTER
to display the memory management menu.
Within the memory management menu, the following items can be consolidated
or executed :
- copy a block
- delete a block
- delete all blocks
- all settings to midposition
- R&B convergence to mid
- Gr convergence mid (only if green convergence is available)
Copy a block
The copy a block function copies the settings of a selected block into the active
block.
Highlight
copy a block
with the control disc and press
ENTER.
To copy the settings of a closed block to the block you are working on (active
block), use the control disc to select a block.
All existing settings will be overwritten with the new settings.
Press
ENTER
to copy the selected block. A confirmation screen will be displayed.
If you are certain you wish to copy the contents of the selected block into the
active block, press
ENTER
.
EXIT
cancels the copy procedure and returns without copying the block.
ENTER displays a confirmation screen.
EXIT returns to the Service Mode main menu.
SERVICE MODE
PROJECTOR SET-UP
COMMON SETTINGS
12C DIAGNOSTICS
MEMORY MANAGEMENT
Select with
then <ENTER>
<EXIT> to return.
or
MEMORY MANAGEMENT
COPY A BLOCK
DELETE A BLOCK
DELETE ALL BLOCKS
ALL SETTINGS TO MIDPOS
R & B CONVERGENCE MID
GR CONVERGENCE MID
Select with
then <ENTER>
<EXIT> to return.
or
MEMORY MANAGEMENT
DELETE A BLOCK
DELETE ALL BLOCKS
ALL SETTINGS TO MIDPOS
R & B CONVERGENCE MID
GR CONVERGENCE MID
Select with
then <ENTER>
<EXIT> to return.
or
COPY A BLOCK
COPY MODE
Nr.
Src
Fh
Fv
inp
conf
1
1
15.6 50
video FC
2
3
31.2 60
RGB3S RT
3
-
15.6 50
intern FC
4
2
31.5 50
RGB3S FC
5
-
33.7 60
intern FC
6
7
8
Active block nr.
1
Select with
then <ENTER>
<EXIT> to return.
or
COPY BLOCK
All settings
in current block
will be overwritten !
Select with
then <ENTER>
<EXIT> to return.
or
ENTER will select the highlighted item.
EXIT returns to the Path Selection main menu.
ADJUST returns to the Operational mode.