background image

Troubleshooting

English  29

Interruption of Electrical 

Service

  If you experience an interruption of electrical service, due to a power surge or other factors, during 

  normal operation of your Rumble Tuff 

®

 Electric Breast Pump, try the following:

  ● Unplug the AC/DC Adapter cord from the electrical outlet and wait for five seconds.

  ● Plug the AC/DC Adapter cord back into the electrical outlet.

  ● If problem persists, try a different electrical outlet.

Radio Frequency Energy

  This equipment generates, uses, and can radiate radio frequency energy. If not installed properly and  

  used in accordance with the instructions; it may cause harmful interference with other devices in the 

  vicinity. Try the following:

  ● Reorient or relocate the device receiving interference.

  ● Increase the distance between the equipment.

  ● Connect the equipment into an outlet on a different circuit from that which the other      

      device(s) are connected.

  ● Consult the manufacturer or a field service technician of the device receiving interference 

      for help.

  ● 

There is no guarantee that interference will not occur.  

Decreased Suction

  If it feels like the suction has decreased, try the following:

  ● Make sure the Breast Pump is assembled correctly 

     (see Assembly Instructions pages 8-13).

    ○ Inspect the One-Way Valve for any tears or pinholes. This component is critical to   

       achieving proper suction. If damaged, replace the One-Way Valve with one of the spare  

       valves that is provided with your Rumble Tuff

 

®

 Electric Breast Pump.

  ● Detach the Tubing and Tubing Adapter from the back of your Electric Breast Pump and place a finger 

      over the Tubing Adapter Inlet. 

    ○ If you do feel suction, the Electric Pump Base is operating properly. 

    ○ If you do NOT feel suction or feel that the suction has decreased to an unexpected strength; contact    

       Rumble Tuff Customer Service for warranty service (see Page 32).

Summary of Contents for Mighty Tyke

Page 1: ...Rumble Tuff Electric Breast Pump Instructions Assembly for Mighty Tyke...

Page 2: ......

Page 3: ...ble milk while you are undergoing medical treatment The Rumble Tuff Electric Breast Pump provides many of the features busy moms love 2 cycles of expressions to mimic baby s nursing patterns Swift Exp...

Page 4: ...Electric pump Diaphragm Kit How to Assemble Expression Collection Combo Kit Power Options Using your AC DC Adapter Using the Li Ion Rechargeable Battery Install the Battery Pumping Instructions LED L...

Page 5: ...Frequency Energy Decreased Suction Pumping Does t Start Breastmilk Buildup in the Breastshield Body Where to get Replacement Parts Where to get Additional Accessories What Additional Accessories are A...

Page 6: ...en Do not drop or hit the product to avoid damage Do not touch the product with bare hands right after sterilizing by boiling water to avoid scalds and burns Do not over boil to avoid premature aging...

Page 7: ...s device Using any other AC DC Adapter or Li Ion battery pack not approved by the manufacturer voids the warranty If you are infected with Hepatitis A Hepatitis B or have HIV Human Immunodeficiency Vi...

Page 8: ...arts Guide Mighty Tyke Breast Pump Main Unit AC DC Adapter Expression Collection Combo Kit Bottle Adapter Kit Vacuum Tube with Adapter English 5 Li Ion Rechargeable Battery Extra 5 oz Collection Bottl...

Page 9: ...ting Button Vacuum Adjusting Button Power Mode Button On Off press and hold for 2 sec Mode press once Swift Expression LED Light Natural Expression LED Lght Battery Cover Tubing Adapter Inlet AC DC Ad...

Page 10: ...ection Combo Kit Parts Guide English 7 Cap Diaphragm Cup with O Ring Breastshield Body One Way Valve Bottle Adapter Collection Bottle Bottle Base Silicone Cushion Electric pump Diaphragm Kit Expressio...

Page 11: ...Hold the horn of the Breastshield Body in one hand Make sure the bottle thread side opening is facing up 2 With the thumb and forefinger of the other hand hold the tip of the One Way Valve and place...

Page 12: ...Valve and shape into a straight line Note This is critical to the performance of the Pump 4 Carefully twist on the Bottle Adapter to the Breastshield Body for a secure fit Note Be sure not to bump the...

Page 13: ...How to Assemble the Expression Collection Kit Continued 5 With the Bottle Adapter in one hand twist on the Collection Bottle for a secure fit English 10...

Page 14: ...p matching the shape of the Cup Press around the edges of the Diaphragm for a secure fit Make sure the Diaphragm is evenly mounted on the Cup and there is no gap in between them 2 Place the Cap on the...

Page 15: ...it clockwise into the Breastshield Body until it locks into place 2 With the Breastshield Body in one hand place the Silicone Cushion in the Breastshield Body matching the shape of the horn Secure the...

Page 16: ...ithout the adapter and connect to the Tubing Connector located on the Cap Push together firmly for a tight seal Note Make sure there is no moisture in the tubing 4 Make sure the Tubing Adapter is prop...

Page 17: ...Unit Your Electric Breast Pump may be operated under any of the following power supply modes Using your AC DC Adapter Electrical safety can only be achieved when using the AC DC Adapter which was prov...

Page 18: ...will charge every time the AC DC Adapter is plugged in however it will not charge while your Electric Breast Pump is in use The Swift Expression LED and Natural Expression LED flash alternately while...

Page 19: ...rrow Lift to remove the cover 2 Use the tab to remove the old battery Note To remove the battery slide the battery down away from the side with the Tubing Adapter Inlet Pull the tab up to remove the o...

Page 20: ...tery is inserted incorrectly When the battery is inserted correctly it will slide easily into the battery compartment Do NOT force 4 Close the Battery Cover and slide the back in place until locked Al...

Page 21: ...e Breastshield 2 Press and hold the Power Mode Button until the pumping starts Note Make sure to hold the Power Mode button long enough approx 2 sec until the pumping starts If this doesn t work pleas...

Page 22: ...light up 4 Adjust the suction to your comfort level while pumping by pressing the buttons or A beep sound can be heard whenever the suction level is changed Note The LED light will flash when you hav...

Page 23: ...e pump will turn off if you press and hold the Power Mode Button for more than 2 seconds 6 The pump will switch to the Natural Expression mode at the lowest suction level The Natural Expression LED wi...

Page 24: ...il the pumping stops Note Make sure to hold the Power Mode button long enough approx 2sec until the pumping stops Make sure there is no suction on the nipple before removing the Breastshield If necess...

Page 25: ...in Natural Expression Blue Light is On Battery is Low Swift Expression mode White Light Flashes Battery is Low Natural Expression mode Blue Light Flashes Battery is Empty Both Blue White Lights Flash...

Page 26: ...Electric Breast Pump or any Expression Collection parts or attachments Make sure all parts are clean and dry Ensure the Tubing is free from any liquid Do NOT operate your Rumble Tuff Electric Breast P...

Page 27: ...water or other fluids inside the Tubing If liquids are found inside Tubing rinse the Tubing with clean hot water Hang to AIR DRY COMPLETELY BEFORE USING Do NOT insert any object into Tubing Note Befor...

Page 28: ...the temperature of the milk on the inside of your wrist before feeding it to your baby The milk should feel warm not hot WHAT TO DO Storing milk in 2 to 4 oz amounts may reduce waste Write the date yo...

Page 29: ...ty of the milk might not be as high Smaller cooler with a blue ice pack 59 F 24 hours Keep ice packs in contact with milk containers at all times limit opening cooler Countertop table Room temp 60 F 8...

Page 30: ...t down while breast feeding and don t even notice the change To achieve multiple let downs which mimics the natural reflex found in breast feeding you can switch back and forth between the Swift Expre...

Page 31: ...an extended period of time store within the following temperature range 32 F to 77 F 0 C to 25 C Breastfeeding Tips The Rumble Tuff Electric Breast Pump helps you maintain a supply of milk and can hel...

Page 32: ...ent into an outlet on a different circuit from that which the other device s are connected Consult the manufacturer or a field service technician of the device receiving interference for help There is...

Page 33: ...91900 0201 Troubleshooting Continued English 30 Pumping Doesn t Start Make sure the adapter is properly plugged If you are using the battery make sure the battery is fully charged When battery runs lo...

Page 34: ...served to disconnect the device not to position the equipment to make it difficult to operate the disconnection device Technical Specifications VACUUM Reflex Swift Expression 115 200mmHg 15 3 26 6kpa...

Page 35: ...ED BY LAW SHALL BE LIMITED IN DURATION TO A PERIOD OF 120 DAYS FROM THE DATE OF PURCHASE BY THE ORIGINAL PURCHASER In the event that this product if found by Rumble Tuff to not meet the above limited...

Page 36: ...tion of the problem You the purchaser are responsible for all shipping charges To obtain an RA and shipping address Please contact Rumble Tuff Customer Service Department by Toll free 855 228 8388 or...

Page 37: ...75 PA20600 RT01 Ver A1407 Rumble Tuff is owned and operated by A Cute Baby Inc 865 N 1430 W Orem UT 84057 6402 Tel 801 609 8168 Fax 801 796 2688 www rumbletuff com www acutebaby com...

Reviews: