Manual
RUKRA Phone line Switch
Article number: RK-2022
3
CALL FROM CABINE
For call use not blocked BTN1.
(Alarm button on/below cabin)
This Button has three function:
1)
Emergency call – press BTN1 longer than time parameter 52 (2sec)
2)
End of alarm – press BTN1 longer than (time parameter 52) x 8 (16sec)
3)
Call to the machine room – three times press button BTN1 (explain in picture)
Picture explain how pressed button for successful call to the machine room.
PROGRAMMING
RUKRA Phone Line Switch is possible programming only from PC with program RUKRA Elevatorphone
Setting. Connector for PC has only 4 pins and we need use reduction between 4 pins connector and
standard 10 pins programming connector. Programming is easy, in program RUKRA Elevatorphone
Setting we have settings for connected Elevator Phones and now we connect RUKRA Phone Line
Switch, and write these parameters (without changes) to the RUKRA Phone Line Switch, so this is all.
These settings we recommended to save to the PC for next other possible future servicing.
Parameters affected thereby: 42 Character prolongation
43 Hang-up code
45 Activate parallel mode
46 Number of RUKRA Elevator Phone (if parallel connected)
4 * Constant time detection
51 Maximum call duration
TECHNICALL
Power
: 12 – 24 VDC
Consumption
: Stand-by 40mA
Active 300 mA at 12V and 150 mA at 24V
Programming
: Only by PC and program “RUKRA Elevator Setting”
Sizes
: 21 x 99 x 66mm
Environment temperature
: -30 to 85° Celsius
CE
: The CE symbol indicates that the product complies with the
European directives.
On our website you can download the declaration of conformity.
Warranty
: 2 year Carry in
RUKRA EUROPE B.V.
WWW.RUKRA.EU
TEL: +31 33 711 39 34