Hardware Installation and Reference Guide
Overview
7
LED
Panel Identification
Status
Meaning
Blinking yellow
The port is receiving or transmitting data at
10/100 Mbps.
1.3 RG-S5760C-48GT4XS-X
Technical Specifications
Model
RG-S5760C-48GT4XS-X
CPU
Dual-core with each 1.2 GHz
BOOTROM
16 MB
Flash Memory
4 MB
SDRAM
1 GB
Optical Module
SFP+ interface
SFP module, SFP BIDI module
SFP+ module, SFP+ cable, SFP+ BIDI module
See
Appendix B
.
The supported module type may update at any time. Please consult Ruijie Networks for
the latest information.
Expansion
Module Slot
1 slot
Supported module: M5000X-4XS2CQ
Power Supply
Module Slot
2 slots
Supported AC module: The switch supports RG-PA150I-F and RG-PA150IB-
F after upgraded to 12.5SPJ4 or later versions. (RG-PA150I-F and RG-PA150IB-
F can be used in combination.)
AC input:
Rated voltage: 100 to 240 V
Maximum voltage: 90 to 264 V
Frequency: 50/60 Hz
Rated current per input: 3 A (150 W power supply)
HVDC input:
Rated voltage: 240 V DC
Maximum voltage: 192 to 288 V DC
Rated current per input: 3 A (150 W power supply)