  Preparations Before Installation   

2.1 

 

Safety Precautions   

To  avoid  the  harms  caused  to  human  and  device,  please  carefully  read  the  safety 

precautions given in this manual before installing RG-AP620-H.     

 

Note 

The  following  safety  precautions  can't  cover  all  possible  hazardous 

conditions.     

2.2 

 

Grounding and Lightning 
Protection     

1. Grounding body   

The grounding body shall adopt hot-galvanized flat steel (or copper), with dimension 

no 

less 

than 

40mm*4mm. 

The 

vertical 

grounding 

body 

shall 

adopt 

50mm*50mm*5mm (minimum) hot galvanized angle bar with length reaching 2.5m; in 

case steel tube is used, the wall thickness must reach at least 3.5mm.     

2. Ground lead   

The ground lead shall adopt 40mm * 4mm or 50mm * 5mm hot-galvanized flat steel 

with length no exceeding 30m.     

3. Grounding bus bar   

The  grounding  bus  bar  shall  be  generally  copper  bar  with  cross-sectional  area  no 

less  than  160mm2.  The  vertical  grounding  trunk  for  high-rise  buildings  shall  adopt 

copper bar with cross-sectional area no less than 300mm2.     

4.  If  the  distance  between  the  grounding  bus  bar  of  respective  floors  and  the 

connecting  wire  of  Local  Expansion  Bus  (LEB)  of  equipment  room  is  rather  short, 

multi-strand copper wire with cross-sectional area being 16mm2 can be used; if the 

distance  is  long,  multi-strand  copper  wire  with  cross-sectional  area  no  less  than 

35mm2 must be used.     

5. The network cable shall adopt shielded cables and devices at both ends shall be 

reliably grounded, while the shielding jacket of network cables shall be grounded as 

possible.  If  network  cables  cannot  be  shielded  as  required,  the  cables  can  be 

Summary of Contents for RG-AP620 Series

Page 1: ...Installation Guide RG AP620 Series Wireless Access Device...

Page 2: ...ten consent of Ruijie Networks is prohibited are registered trademarks of Ruijie Networks Counterfeit is strictly prohibited Exemption statement This document is provided as is The contents of this do...

Page 3: ...modules Chapter 2 Preparation Before Installation lists safety power supply and site requirements that must be met before you install the switch Chapter 3 Installation describes how to install the swi...

Page 4: ...vices Customer service center of Ruijie Networks which can provide all customers with needed technical assistance for products technologies and solutions The customer service center provides responsiv...

Page 5: ...it can also act a FAT AP and provide wireless access service for WLAN users 1 2 Key Technical Indicators of RG AP620 H Table 1 1 Technical indicators of AP620 H wireless AP Model No RG AP620 H Applic...

Page 6: ...at ambient temperature of 40 55 and without water immersion 1 3 Detailed Introduction to AP620 H Wireless AP 1 3 1 AP620 H Wireless AP 1 3 1 1 Physical Appearance The front panel of AP620 H provides...

Page 7: ...interface 2 1000Base X SFP port 3 10 100 1000Base T self adaptive Ethernet port 1 3 1 3 Power System AP620 H adopts POE input and complies with 802 3at protocol Input voltage range 36 57V Rated curren...

Page 8: ...50mm 5mm hot galvanized flat steel with length no exceeding 30m 3 Grounding bus bar The grounding bus bar shall be generally copper bar with cross sectional area no less than 160mm2 The vertical groun...

Page 9: ...le L and N lines must not be reversed 2 3 Site Selection AP620 H shall not be installed in heated dusty inflammable or explosive environment or at sites with noxious gases electromagnetic interference...

Page 10: ...oof Considerations 1 For unused interfaces the corresponding waterproof plugs shall be processed use waterproof tape to rewind the screw thread of waterproof plug for three loops and then seal the unu...

Page 11: ...e conducted interference is incurred when the interference source and the sensor are connected via magnet wire or signal cable and the interfering signal is transmitted from one unit to the other unit...

Page 12: ...nected to the receiving interface of counterpart device while the receiving interface of this device shall be connected to the transmitting interface of counterpart device 2 9 Installation Tools Table...

Page 13: ...on Flow 3 2 Verifications Before Installation Verify the following points before the installation Whether the installation site satisfies the requirements on temperature and humidity Whether the insta...

Page 14: ...rear of main unit and tighten the screws on the mounting bracket as shown below Figure Fix the mounting bracket to the rear of AP620 H and tighten the screws on the mounting bracket Prepare to mount t...

Page 15: ...Parallel installation Vertical installation...

Page 16: ...of mounting holes on the mounting bracket Put the U hoop in respective holes according to the mode of installation and lock screws to mount AP620 H onto the hold pole Mounting holes on the bracket Pa...

Page 17: ...Vertical installation Tighten the screws to fix the hoop...

Page 18: ...to the group 3 Properly ground the hold pole by using 40mm 4mm flat steel to connect the pole to the lightning protection ground mat and make sure the joint between flat steel and ground mat is rustl...

Page 19: ...ered by the 45 degree protection angle of the lightning arrester Install outdoor all directional antenna 3 Directly install all directional outdoor antenna on the main unit When small gain mast type a...

Page 20: ...2 After that prepare the modular plug...

Page 21: ...of the twisted pairs used by the 1000BASE T port Figure A 1 Four twisted pairs of the 1000BASE T Straight Through Crossover Switch Switch 1TP0 1TP0 2TP0 2TP0 3TP1 3TP1 6TP1 6TP1 4TP2 4TP2 5TP2 5TP2 7T...

Page 22: ...of the 100BASE TX 10BASE T 2 Fiber Connection For the optic ports select single mode or multiple mode fibers for connection according to the fiber module connected The connection schematic diagram is...

Page 23: ...s and technical specification Mini GBIC SFP Wavele ngth nm Media Type Core Size nm Bandwid th MHz k m Maximu m cabling distance Optical Intensity dBm MAX Reception sensitivity dBm MAX Standard FE SFP...

Page 24: ...km 5 9 Mini GBIC GT N A CAT 5 UTP N A N A 100m N A N A Warning For the optical modules that the maximum cabling distance exceeds 40km including 40km when using the short distance single mode fiber the...

Reviews: