Ruijie RG-AP130(W2) V2 Series Hardware  Installation And Reference Manual Download Page 15

·

 

Hardware Installation and Reference Guide                                                                                                      System Debugging 

 

 

4.2  Powering Up the AP 

4.2.1  Checking before power-up 

 

Verify that the input voltage matches the specification of the AP.   

4.2.2  Checking after power-up 

After powering up, it is recommended that you check the following items to ensure normal operation of the AP.     

 

The LED on a normally-working AP gets blinking green first. After 60s, the LED turns solid green. 

Figure 4-3 LED on the AP 

 

4.2.3  Reset/Restore Default Settings 

The reset button is hidden in a hole and used by  technical support personnel. To avoid abnormal operation, do not use 

this button without consultation with technical support personnel. 

Figure 4-4 Reset Button on the AP 

 

4.2.4  System Reset 

Insert an iron stick, 1mm or less in diameter, into the hole, and slightly press it. After hearing a click, keep the stick in the 

same position for 2s to reset the system. 

4.2.5  Restore Default Settings 

Insert an iron stick, 1mm or less in diameter, into the hole, and slightly press it. After hearing a click, keep the stick in the 

same position for 3s. The system reset is complete. 

 

LED 

Reset Button 

Summary of Contents for RG-AP130(W2) V2 Series

Page 1: ...Ruijie RG AP130 W2 V2 Series Access Points Hardware Installation and Reference Guide 1 00...

Page 2: ...or by any means without the prior written consent of Ruijie Networks is prohibited Exemption statement This document is provided as is The contents of this document are subject to change without any n...

Page 3: ...ty https community ruijienetworks com Technical Support Email service_rj ruijienetworks com Skype service_rj ruijienetworks com Related Documents Documents Description Configuration Guide Describes ne...

Page 4: ...1 Technical Specifications Table 1 1 Technical Specifications of RG AP130 W2 V2 Hardware Specifications Radio 2 4G 2 x 2MIMO 5G 2 x 2SU MU MIMO Transmission Protocol 2 4G 802 11b g n 5G 802 11a n ac...

Page 5: ...g 0 C to 45 C 32 F to 113 F Storage 40 C to 70 C 40 F to 158 F Humidity Operating 10 to 95 RH non condensing Storage 5 to 95 RH non condensing Installation Ceiling wall mount in a 86 type faceplate IP...

Page 6: ...2 V2 PoE UpLink port which is on the rear is the 10 100 1000Base T WAN port PoE capable Four 10 100 1000Base T LAN ports are on the bottom Figure 1 2 Side View of RG AP130 W2 V2 Note 1 Reset button 2...

Page 7: ...linking green 0 4Hz AP is operational and CAPWAP connection is established At least one client is associated Reset button Pressed for less than 2s Reboots the device Pressed for more than 3s Restores...

Page 8: ...57V Rated current 0 25A DC power supply Input voltage range 12V Rated current 1A When powered through PoE the AP can be used with Ruijie s other products supporting 802 3af PoE 1 5 Cooling Solution Th...

Page 9: ...ters away from the seaside and do not face it toward the wind from the sea The installation site should be free from water flooding seepage dripping or condensation The installation site shall be sele...

Page 10: ...ference source can be both a part of the interfered system and a completely electrically isolated unit Conducted interference results from the electromagnetic wire or signal cable connection between t...

Page 11: ...have been met 3 1 Installation Flowchart 3 2 Before You Begin To ensure normal operation and a prolonged useful life of the equipment observe the following safety precautions Install the device in a...

Page 12: ...he device before install or move it Make sure that the screws are of fine quality Be sure that the equipment is installed in a place where it is easy to be observed 1 Loosen screws on the 86 type face...

Page 13: ...Access Point 3 Connect the uplink cable to the UpLink port Figure 3 3 Tighten Screws with a Screwdriver 4 Slide down the AP into the plate Figure 3 4 Mounting the AP into the Plate 5 Use an M3x4 screw...

Page 14: ...ink port WAN on the AP Figure 4 1 Connect the Ethernet Cable to the UpLNK Port DC power adapter power supply When applying DC power supply plug one end of the Ethernet cable into the PoE UpLink port a...

Page 15: ...Restore Default Settings The reset button is hidden in a hole and used by technical support personnel To avoid abnormal operation do not use this button without consultation with technical support pe...

Page 16: ...lty Blinking green 0 4Hz The AP is operational The CAPWAP connection is OK At least one client is associated with the AP Blinking green one flash every 4 seconds The AP is operational No clients are a...

Page 17: ...le is connected Verify that the device at the other end of the Ethernet cable is working properly And then verify that the Ethernet cable is capable of providing the required data rate and is properly...

Page 18: ...imum distance of 100 meters 328 feet 1000BASE T requires all four pairs of wires be connected for data transmission as shown in Figure A 1 Figure A 1 1000BASE T Connection 10BASE T uses Category 3 4 5...