Scope 

It is intended for the users that have some experience in installing and maintaining network 

hardware and want to learn the above information. At the same time, it is assumed that the users of 

this switch are already familiar with the related terms and concepts of Ethernet. 

 

Product Overview 

RG-S12000 Series Ethernet switches, the modular high-capacity multi-service IPv6 10G core 

routing switches independently researched and developed by Ruijie Networks, provide users with 

powerful security protection and stacking expansion capability on service demand, so as to satisfy 

the needs of both the service and performance. 

RG-S12000 series Ethernet switches support dual management boards and power supply 

redundancy, providing two kinds of hosts with 10 vertical slots and 6 horizontal slots respectively: 

RG-S12000 and RG-S12006. 

 

RG-S12010 supports dual management engine modules and provides 8 service module slots. 

 

RG-S12006 supports dual management engine modules and provides 4 service module slots. 

Safety Precautions for Movement 

RG-S12000 Series is large and heavy. When you carry them, please pay attention to the following 

requirements:  

 

Remove all power cables before you move the switch. Note: There may be more than one 

power cable. 

 

Plug out power, fan and service modules to reduce the chassis weight before moving the switch 

for a long distance. 

 

At least two people are needed to move the switch. Do not attempt to move the switch by one 

person only.   

 

Keep balance when moving the switch by two people, and keep the pace with each other.   

 

Grasp the handles on both sides of the rack, not the power system handle, fan handle and the 

back panel handle. Those handles are used to install and remove corresponding parts, not to 

bear the whole switch weight.   

 

The whole switch weight may be higher than 80kg during the movement. 

 

To correctly move the RG-S12010, refer to the Figure 2-1. And for the RG-S12006 Series, refer 

to Figure 2-2. Note that the following figures are just the schematic diagrams, do not insert the 

board and power supply when moving the chassis to avoid the chassis weight increment or 

board damage. 

 

 

Summary of Contents for RG-S12000 Series

Page 1: ...RG S12000 Series Switches Quick Installation Guide V1 22...

Page 2: ...ten consent of Ruijie Networks is prohibited are registered trademarks of Ruijie Networks Counterfeit is strictly prohibited Exemption statement This document is provided as is The contents of this do...

Page 3: ...ocuments Documents Description Configuration Guide Describes network protocols and related mechanisms that supported by the product with configuration examples Command Reference Describes the related...

Page 4: ...tion Requirements 8 Checking Before Installation 10 Fan 11 Power Supply 11 Specification 11 Precaution 11 System Grounding 11 Grounding Requirements 11 Grounding description 12 Rack grounding pole 12...

Page 5: ...rectly looking at the optical interfaces or fibers may damage your eyes Serial Interface Safety Warning Hot plugging in a serial interface may damage your terminal Please power off the terminal before...

Page 6: ...ngine modules and provides 4 service module slots Safety Precautions for Movement RG S12000 Series is large and heavy When you carry them please pay attention to the following requirements Remove all...

Page 7: ...damage you must pay attention to the following Proper grounding of the switch and floor Dust prevention measures are taken in the room An appropriate humidity is maintained Do not wear loose clothes...

Page 8: ...l fibers and distribution cables Connect the interfaces Ruler long tapeline marker pen Measure the installation position Common tools Bolts diagonal pliers straps Mount the chassis Anti static tool Pr...

Page 9: ...ent spacing is reserved at the ventilation openings to ensure normal heat dissipation After various cables have been connected they should be arranged into bundles or placed on the cabling rack to avo...

Page 10: ...not grounded reliably or the ground is wet Keep the switch away from wet or liquid Be aware of the emergent power switch in the room Once an accident occurs shut down the power switch Make sure that...

Page 11: ...bles to connect power modules The dust in the air may block the air outlet of an air filter after the air filter is used for a long time thus affecting system ventilation and heat dissipation It is re...

Page 12: ...bank Lightning prevention ground prevents lightning shock The lightning prevention system of general equipment is a separate system composed of lightning rod down conductor and grounding system Figure...

Page 13: ...ounding pole of the chassis The antistatic wrist strap jack is located on the front panel of the chassis marked with yellow ESD 4 The antistatic wrist strap is grounded well and the DC electric resist...

Page 14: ...d the Alarm LED is red Troubleshooting 1 Check if the supervisor engine gets loose If so install the supervisor engine again and ensure that it is inserted tightly before you tighten the fastening scr...

Page 15: ...Input delete config text Press Enter 5 The Are you sure you want to delete config text No yes is shown on the interface Input y and press Enter to delete it 6 Input dir to view current file configurat...

Page 16: ...connected to the receiving end of the other optical interface You can check by changing the sequence in which the two optical fibers are connected on the optical module 2 Check whether the optical mod...

Reviews: