be saved in this Data Group.in the meanwhile t
he Data Group Number is shown on the right
hand side of the screen
.
Press
key to exit.
1.6.2.4 M-PRE ON / OFF Setting
Switch to
, press and turn the rotary control to Data Group Number you want
to check, then all the data will be shown to you, press rotary control again so that you can
adjust M-PRE option. Turn the rotary control to select either ON or OFF. When ON is selected
it signifies that when the Data Group is recalled the state of the unit main output will remain
the same as it was prior to the Data Group recall. When OFF is selected it signifies that when
the Data Group is recalled the state of the unit main output will be set to OFF regardless of
previous setting.
1.6.2.5 Output Status Setting
Switch to
, press and turn the rotary control to select either ON or OFF. When
ON is selected, the device will Power on with the Output enabled. Selecting When OFF is
selected, the device will Power on with the Output disabled.
1.7 Function Description
1.7.1 Enable or Disable the Output
At any time you can press
key to enable or disable the Output when the keypad is
unlocked.
1.7.2 Locking the Keypad to Avoid Accidental Operation.
At any time you can hold the rotary control for more than 2 seconds to lock the keypad,
there will be
displayed on the right side of the interface; hold the rotary control again
for more than 2 seconds you can unlock the keypad, there will be
displayed on the
right side of the interface.
1.7.3 10 Data Groups Preset
(
M0-M9
)
The M0 Data Group is the default Data Group after power on. It should be noted that
any time an alternative Data Group is selected or any changes made to the existing settings
then M0 will be immediately overwritten with the newly selected data.