RuiDeng DPS3003 Instruction Manual Download Page 1

Constant Pressure/ Constant Current

Digital Power Supply Introductions

Model: DPS3003/DPS3005/DPS5005/DPS8005

version: 2019-3-15

Dear users, thank you for purchasing the constant Voltage/constant Current digital power

supply produced by HANGZHOU RUIDENG TECHNOLOGIES CO., LTD, in order to let you know

more about the full function of this product, get a better experience and avoid misuse.

Please spend some time on reading this introduction. Keep it for checking again.

(Please pay

attention to these red sentences)

1. Production Introduction

1.1 Production Synopsis

This product combines analog adjustment and digital control, at the same time it is

compact and powerful, and becomes the first choice for many enthusiasts and laboratory

workers.

The unit offers non-volatile power off parameter storage and 10 programmable

preset memory Data Groups with a shortcut recall function for groups 1 and 2. All these

productions are designed with LCD display, so we can check set Voltage, set Current, output

Voltage, output current, output power, input Voltage and so on. On the right side of the main

interface, we can see output enabled or disabled, Constant Current or Constant Voltage

mode of operation, abnormal condition warning, keypad locked or unlocked state and the

Data Group in use. The data setting interface allows adjustment of Over-Current,

Over-Voltage and Over-Power protection values, Preset value, LCD brightness and whether

the power is turned on or the like.

This product has 3 versions, Non-communication version, USB communication version,

USB + Bluetooth communication version. Communication version can be connected to PC,

Bluetooth version can be connected to Android mobile phone.

(Note: DPS3003 only has no

communication)

This product has many advantages, small size, advanced function, good visual effect,

high operability, high-precision, it can be used independently or be inset into the device and

been widely applied.

1.2

Series Product Parameters

Model Name

DPS3003

DPS3005

DPS5005

DPS8005

Input Voltage range

DC6-40V

DC6-40V

DC6-55V

DC10-90V

Output Voltage range

0-32.00V

0-32.00V

0-50.00V

0-80.00V

Output power range

0-96W

0-160W

0-250W

0-408W

Output Current range

0-3.000A

0-5.000A

0-5.000A

0-5.100A

Output Voltage

accuracy

±(0.5%+3 digit)

Summary of Contents for DPS3003

Page 1: ...utput power input Voltage and so on On the right side of the main interface we can see output enabled or disabled Constant Current or Constant Voltage mode of operation abnormal condition warning keypad locked or unlocked state and the Data Group in use The data setting interface allows adjustment of Over Current Over Voltage and Over Power protection values Preset value LCD brightness and whether...

Page 2: ...Input negative OUT Output positive OUT Output negative The module is DC DC step down output It must ensure that the input Voltage is 1 1 times higher than output Voltage Under natural heat dissipation conditions it can be output at full load Please install a fan in the casing DC 90 00V is the maximum input Voltage limit and AC or AC Mains supply 220V must NEVER under any circumstances be connected...

Page 3: ...oltage M Keypad locked or unlocked prompt I The actual value of the output Current N Normal or abnormal status prompt J The actual value of the output Power O Constant Voltage or Constant Current status prompt K The actual value of the input Voltage P Data Group number in use prompt Q Output enabled or disabled prompt R Preset Output Voltage V Preset Over Power protection value S Preset Output Cur...

Page 4: ...ltage Protection Over Current Protection or Over Power Protection limits We can set the value of Over Voltage protection value Over Current protection value and Over Power protection value When any of the protection value limits are reached the output will be automatically disabled and there will be displayed on the interface When the temperature of Power board exceeds 80 the output will be automa...

Page 5: ...turn the rotary control to select either ON or OFF When ON is selected the device will Power on with the Output enabled Selecting When OFF is selected the device will Power on with the Output disabled 1 7 Function Description 1 7 1 Enable or Disable the Output At any time you can press key to enable or disable the Output when the keypad is unlocked 1 7 2 Locking the Keypad to Avoid Accidental Oper...

Page 6: ...d throght USB or Bluetooth The two communication methods cannot be used at the same time If you need secondary development communication protocol Download address is detailed in section 2 4 You must download the file from the link we provided 2 1 Driver Installation Open the file and double click CH341SER EXE to install the communication board driver When the driver is installed connect digital po...

Page 7: ...e data press key twice to exit the communication parameters will be saved automatically COMM communicate switch setting ON means to turn on communication OFF means to turn off communication ADDR address code of digital power supply range 001 255 default 001 it won t be used unless multi machine communication BAUD communication Baud rate 2400 4800 9600 19200 can be chosen BPIN Bluetooth pairing cod...

Page 8: ...ts to flash after the digital power is turned on that means the Bluetooth can be searched Open the Bluetooth of your computer right click on the Bluetooth icon to add the device Laptop can use its own Bluetooth desktop can use the recommended USB Bluetooth adapter the USB adapter driver will be automatically installed after plugging in the desktop You can see Bluetooth icon appears in the desktop ...

Page 9: ...terface to connect Bluetooth module again after power on If the LED on Bluetooth module is flashing it shows it is on the state of disconnection If LED is lighting it shows it is on the state of connection When using Bluetooth function don t put Bluetooth module in the metal box otherwise it will affect signal strength Bluetooth communication distance is up to 10 meters in an open and unobstructed...

Page 10: ...g8k2c03llj DPS3005_file DPS5005 file download link http www mediafire com folder napmdzd4qt2dt DPS5005_file DPS8005 file download link http www mediafire com folder i1766ch7ec97a DPS8005_file 2 4 1 Open and Unzip the PC software Double click the Arial Unicode MS Font Pack and click Install to install the Font Pack 2 4 2 Double click setup exe to Set up Computer Software ...

Page 11: ...on 2 3 for Bluetooth connection section 2 1 for USB connection baud rate slave address default 9600 001 click On Line to start communication and automatically lock the digital power button after successful connection Then On Line will change into disconnect Click Turn On to turn on the output of the digital power supply Turn On will change into Turn Off when succeed ...

Page 12: ...stment voltage and current curve derivation You can set Voltage Current by turning the knob or enter an value The graph on the right shows the real time voltage and current curves the curve will be stored for up to 24 hours Put the cursor on the Output Voltage curve table right click and you can see functions below Note you can only right click on the table of DPS8005 others do not have this funct...

Page 13: ...l clean chart data as shown below Automatic adjustment of the X scale will adjust the X axis scale automatically as shown below Exporting data to the clipboard will copy the data to the clipboard Exporting data to Excel will export data as table file as shown below ...

Page 14: ...Exporting simplified image as shown below Advanced functions include data group reading and writing automatic test voltage scan current scan and so on ...

Page 15: ...mestic customers who cannot use Google Store can also download the file with the extension APK and install it on the phone You can get download address in section 2 4 3 1 2 Application Setup Android APP can only work in Android 5 0 or above When installing the software please approve permission that APP needs If you need to record data for a long time please turn off the power saving mode of the m...

Page 16: ...tion button or connect the Bluetooth on the phone first then turn on the app Bluetooth connection to connect to the Bluetooth directly AD program information Version number description assistance developer information AE Voltage Current measurement graph AF output status constant voltage constant current state keypad status AG screen brightness adjust the brightness from 0 to 5 where 0 is the dark...

Page 17: ...4 Others APP for IOS has not been finished You can send E Mail to 1749808860 qq com if you have any question ...