Technical Specifications
3 Technical Specifications
3.1 Operating Environment
Parameter
Range
Comments
Ambient Operating
Temperature
-40 to 85
C
Ambient Temperature as
measured from a 30 cm radius
surrounding the center of the
RS400 Series enclosure.
Ambient Relative Humidity
5% to 95%
Non-condensing
Ambient Storage
Temperature
-40 to 85
C
3.2 Power Supply Specifications
Power Supply Type
Minimum
Input
Maximum
Input
Fuse
Rating
Maximum
Power
Consumption
12 -24 VDC
10 VDC
36 VDC
6.3A(F)
2
24 VDC
18 VDC
36 VDC
5A(F)
2
48 VDC
36 VDC
59 VDC
2A(T)
2
HI (125/250 VDC)
1
HI (110/230 VAC)
1
88 VDC
85 VAC
300 VDC
265 VAC
2A(T)
1,2
8 W
NOTES:
1. This is the same power supply for both AC and DC.
2. (F) Denotes fast-acting fuse, (T) denotes time-delay fuse
3. For continued protection against risk of fire, replace only with same type and
rating of fuse.
29
RuggedCom
®
RuggedServer™
RS400 Family Installation Guide rev109