4. Technical Specifications
RuggedCom® RuggedBackbone™
39
RX1510 Installation Guide Rev 104
4. Technical Specifications
4.1. Power Supply Specifications
Input Range
Power
Supply Type
Min
Max
Internal
Fuse Rating
Max. Power
Consumption
a
Max Power
Output
Connections
88 VDC
300 VDC
HI
85 VAC
264 VAC
2A(T)
b
52W Max
42W
Screw
terminal block
88 VDC
300 VDC
HIP
85 VAC
264 VAC
2A(T)
b
52W Max
42W
Pluggable
terminal block
24
10 VDC
36 VDC
2A(T)
b
52W Max
42W
Screw
terminal block
24P
10 VDC
36 VDC
2A(T)
b
52W Max
42W
Pluggable
terminal block
48
36 VDC
72 VDC
2A(T)
b
52W Max
42W
Screw
terminal block
48P
36 VDC
72 VDC
2A(T)
b
52W Max
42W
Pluggable
terminal block
a
Power consumption varies based on configuration.
b
(T) denotes time-delay fuse.
Table 4.1. Power Supply Specifications
4.2. Critical Alarm Relay Specifications
Voltage
Current
30VDC
5A
250VAC
6.25A
Table 4.2. Form C Contact Relay Specifications
4.3. Copper Ethernet Port Specifications
The RX1510 can be ordered with several different modules which contain 10/100Tx or
10/100/1000Tx Ethernet ports. All copper Ethernet ports have the following specifications:
Parameter
Specification
Notes
Speed
10/100 or 10/100/1000 Mbps
Auto-negotiating
Duplex
FDX / HDX
Auto-negotiating
Cable-Type
> Category 5
Shielded/Unshielded
Wiring Standard
TIA/EIA T568A/B
Auto-Crossover, Auto-Polarity
Max Distance
100 m
Connector
RJ45
Isolation
1.5kV
RMS 1-minute
Table 4.3. Copper Ethernet Port Specifications