RUGGEDCOM RSG2488
User Guide
Chapter 3
Device Management
Resetting the Device
91
IMPORTANT!
Non-Controlled (NC) versions of ROS can not be downgraded to Controlled firmware versions.
However, Controlled firmware versions can be downgraded to an NC firmware version.
CAUTION!
Do not downgrade the ROS boot version.
1. Disconnect the device from the network.
2. Log in to the device as an admin user. For more information, refer to
.
3. Make a local copy of the current configuration file. For more information, refer to
IMPORTANT!
Never downgrade the ROS software version beyond ROS v4.0 when encryption is enabled. Make
sure the device has been restored to factory defaults before downgrading.
4. Restore the device to its factory defaults. For more information, refer to
Section 3.4, “Restoring Factory
5. Upload and apply the older firmware version and its associated FPGA files using the same methods used to
install newer firmware versions. For more information , refer to
Section 3.12.1, “Upgrading Firmware”
.
6. Press
Ctrl-S
to access the CLI.
7. Clear all logs by typing:
clearlogs
8. Clear all alarms by typing:
clearalarms
IMPORTANT!
After downgrading the firmware and FPGA files, note the following:
• Some settings from the previous configuration may be lost or reverted back to the factory
defaults (including user’s passwords if downgrading from a security related version), as those
particular tables or fields may not exist in the older firmware version. Because of this, the unit
must be configured after the downgrade.
• A standard banner will appear on the login screen instead of a custom banner.
9. Configure the device as required.
Section 3.13
Resetting the Device
To reset the device, do the following:
1. Navigate to
Diagnostics > Reset Device
. The
Reset Device
form appears.