13
13
1-
P
ha
se
C
X1
T
ec
hnic
al Da
ta
Model
kW (Btu/hr)
U
nit
V
olt
ag
e
Gas Group
S
upply
Wi
re
S
iz
e ***
U
ni
t Cu
rre
nt
M
ax.
Cir
cui
t
Fu
se
*
C
ab
in
et
Le
ng
th
Te
mp
er
at
ur
e
C
o
de
IIB +
H2
IIB
IIC
V
w/o
T'stat
w/
T'stat
w/o
T'stat
w/
T'stat
AWG
A
A
in (mm)
CX1-400160-0125-T3
1.25 (4565)
400
+
+
14
3.1
15
31.3 (796)
T3 (200)
CX1-400160-018-T3
1.8 (6142)
400
14
4.5
15
31.3 (796)
T3 (200)
CX1-400160-025-T2A
2.5 (8530)
400
+
+
14
6.3
15
31.3 (796)
T2A (280)
CX1-400160-0333-T3
3.33 (11362)
400
+
+
14
8.3
15
49.5 (1256)
T3 (200)
CX1-400160-0347-T3
3.47 (11840)
400
14
8.7
15
71.8 (1823)
T3 (200)
CX1-400160-036-T3**
3.6 (12284)
400
14
9.0
15
49.5 (1256)
T3 (200)
CX1-400160-048-T2A
4.8 (16378)
400
14
12.0
15
49.5 (1256)
T2A (280)
CX1-400160-050-T3
5.0 (17060)
400
12
12.5
20
71.8 (1823)
T3 (200)
CX1-400160-0528-T2A
5.28 (18016)
400
+
+
12
13.2
20
59.5 (1511)
T2A (280)
CX1-400160-0694-T3
6.94 (23680)
400
N/A
10
17.4
25
71.8 (1823)
T3 (200)
CX1-400160-076-T2A
7.6 (25932)
400
N/A
10
19.0
30
59.5 (1511)
T2A (280)
CX1-400160-100-T2A
10.0 (34121)
400
N/A
N/A
8
25.0
35
71.8 (1823)
T2A (280)
CX1-415160-009-T3
0.9 (3071)
415
+
+
14
2.2
15
31.3 (796)
T3 (200)
CX1-415160-012-T3
1.2 (4095)
415
14
2.9
15
31.3 (796)
T3 (200)
CX1-415160-0135-T3
1.35 (4606)
415
+
+
14
3.3
15
31.3 (796)
T3 (200)
CX1-415160-018-T3
1.8 (6142)
415
14
4.3
15
31.3 (796)
T3 (200)
CX1-415160-0269-T2A
2.69 (9179)
415
+
+
14
6.5
15
31.3 (796)
T2A (280)
CX1-415160-0359-T3
3.59 (12250)
415
+
+
14
8.7
15
49.5 (1256)
T3 (200)
CX1-415160-036-T3**
3.6 (12284)
415
14
8.7
15
49.5 (1256)
T3 (200)
CX1-415160-0374-T3
3.74 (12761)
415
14
9.0
15
71.8 (1823)
T3 (200)
CX1-415160-048-T2A
4.8 (16378)
415
14
11.6
15
49.5 (1256)
T2A (280)
CX1-415160-050-T3
5.0 (17060)
415
14
12.0
15
71.8 (1823)
T3 (200)
CX1-415160-0568-T2A
5.68 (19381)
415
+
+
12
13.7
20
59.5 (1511)
T2A (280)
CX1-415160-0747-T2A
7.47 (25488)
415
N/A
10
18.0
25
71.8 (1823)
T2A (280)
CX1-415160-076-T2A
7.6 (25932)
415
N/A
10
18.3
25
59.5 (1511)
T2A (280)
CX1-415160-100-T2A
10.0 (34121)
415
N/A
N/A
8
24.1
35
71.8 (1823)
T2A (280)
CX1-480160-012-T3
1.2 (4095)
480
14
2.5
15
31.3 (796)
T3 (200)
CX1-480160-018-T3
1.8 (6142)
480
14
3.8
15
31.3 (796)
T3 (200)
CX1-480160-036-T3**
3.6 (12284)
480
14
7.5
15
49.5 (1256)
T3 (200)
CX1-480160-048-T2A
4.8 (16378)
480
14
10.0
15
49.5 (1256)
T2A (280)
CX1-480160-050-T3
5.0 (17060)
480
14
10.4
15
71.8 (1823)
T3 (200)
CX1-480160-076-T2A
7.6 (25932)
480
N/A
12
15.8
20
59.5 (1511)
T2A (280)
CX1-480160-100-T2A
10.0 (34121)
480
N/A
10
20.8
30
71.8 (1823)
T2A (280)
CX1-600160-012-T3
1.2 (4095)
600
N/A
14
2.0
15
31.3 (796)
T3 (200)
CX1-600160-018-T3
1.8 (6142)
600
N/A
14
3.0
15
31.3 (796)
T3 (200)
CX1-600160-036-T3**
3.6 (12284)
600
N/A
14
6.0
15
49.5 (1256)
T3 (200)
CX1-600160-048-T2A
4.8 (16378)
600
N/A
14
8.0
15
49.5 (1256)
T2A (280)
CX1-600160-050-T3
5.0 (17060)
600
N/A
14
8.3
15
71.8 (1823)
T3 (200)
CX1-600160-076-T2A
7.6 (25932)
600
N/A
12
12.7
20
59.5 (1511)
T2A (280)
CX1-600160-100-T2A
10.0 (34121)
600
N/A
N/A
10
16.7
25
71.8 (1823)
T2A (280)
5.
For IIB model with Defender® built-in thermostat - Class I, Div. 1 & 2, Groups C &
D; Zones 1 & 2, Groups IIA and IIB.
6.
For IIC model with XT built-in thermostat - Class I, Div. 1 & 2, Groups A,B,C & D;
Zones 1 & 2, Groups IIA, IIB, IIC.
7.
IIC Grouping units come with x-Max® housing.
8.
Remote mounted, Defender, explosion-proof room thermostats are not suitable
for Group B & IIC applications.
9.
Remote contactors are required on all 600V heaters, and heaters with a current
draw greater than 22 amps (supplied & installed by others), when utilizing XT-311
remote thermostat.
10. Temperature code ratings: T2A - 280°C (536°F), T3 - 200°C (392°F)