4) 

 

 Examine the valve body for any 
damage such as burrs, nicks, etc. 
Replace if damaged.  

 
5)  Examine the ball (Item 5) and seat 

(Item 11) and replace if  worn-out. 

 
6) Replacement seals from a Ruelco 

product repair kit are required for 
proper valve   performance. 

It  is 

recommended that all seals be 
lubricated before and after 
 

installation with a high quality 

silicon base grease. 

 
7)

 

 Lubricate the body seal (Item 2) and 
install on the cap (Item 1). 

  
 
 
 
 
 

 
 
8) Lubricate the shaft O-rings and 

install on the spool assembly along 
with the teflon back-ups (Item 10). 

 
9) Lightly lubricate the bores in the 

valve body (Item 8). 

 
10)

 

  Lubricate the seat O-ring (Item 3) 
and install on the seat (Item 11). 

  
11)  Push the spring (Item 6) inside the 

spool (Item 7) and thread the seat 
(Item 11) along       with the ball 
(Item 5) onto the spool. 

 
12) Push the spool-assembly (Item 7) 

inside the valve body (Item 8). 

 
13) Thread the cap (Item 1) onto the 

valve body (Item 8).  

 
 

V. RECOMMENDED 

MAINTENANCE 

 

PROCEDURE    

 

 

 

 

 

 

 

INTERVAL 

 
Operate 

Manually.        Every 

30 

days. 

Disassemble, inspect and lubricate.  

 

 

 

Yearly or as required. 

Replace 

all 

seals. 

        Every 

two 

(2) 

years 

or 

as 

required.

 

 

ii