Copyright © 2015 Ruckus Wireless, Inc.
Published September 2015, Part Number 800-70564-002 Rev C
Page 3 of 4
Mounting on a Recessed Drop-Ceiling T-Bar
The enclosed T-bar bracket supports mounting to recessed drop ceiling
T-bars.
•
Mounting an AP using the External Bracket
•
Removing an External Bracket from a T-Bar
•
Removing an External Bracket from an AP
Mounting an AP using the External Bracket
1
Insert the unit removal pin (A in
) into the hole on the
side of the Unleashed R500 (B in
) to release the
locking mechanism.
Figure 10. . Attaching the external bracket to the AP
2
Position the studs on the bottom of the T-bar bracket (C in
) in the mounting holes on the Unleashed R500
enclosure, and then slide the T-bar bracket until the studs are in
the narrow parts of the Unleashed R500 mounting keyholes
(arrow).
3
Remove the unit removal pin (A in
) to engage the
locking mechanism and secure the T-bar bracket to the
Unleashed R500.
4
Make sure that the locking tab (D in
) is in the first
position on the T-bar bracket (C in
5
Gently push the ceiling tiles up and out of the way.
6
Position the T-bar bracket so its two clasps grip one edge of
the T-bar (A in
). Make sure that both clasps are
gripping the T-bar.
Figure 11. . Attaching the external bracket to the T-bar
7
Hold the Unleashed R500 in place and gently push the locking
tab (B in
) until its clasp grips the other edge of the T-
bar.
Removing an External Bracket from a T-Bar
1
Move the ceiling tiles out of the way.
2
Gently lift up the locking tab (A in
) by sliding your
fingers under the tab.
3
While lifting up on the locking tab, rotate the Unleashed R500-
and-T-bar bracket assembly (B in
). The Unleashed
R500-and-T-bar bracket assembly comes away from the T-bar.
Figure 12. . Removing the external bracket from the T-bar
Removing an External Bracket from an AP
1
Insert the unit removal pin (A in
) into the hole on the
side of the Unleashed R500.
2
Gently lift up the retainer tab (B in
3
Gently push the T-bar bracket (C in
) until it detaches
from the Unleashed R500.
Figure 13. . Removing the external bracket from an AP
Mounting on a Flush Drop-Ceiling T-Bar
•
Mounting an AP using the Integrated Bracket
•
Removing an AP Integrated Bracket from a T-Bar
Mounting an AP using the Integrated Bracket
1
Orient the AP so that the T-bar is positioned between the T-bar
clips as shown in
, then rotate the AP until the third
T-bar clip catches the T-bar and the latch locks the T-bar in
place (
Figure 14. . Attaching the integrated bracket to the T-bar
Figure 15. . Locking the integrated bracket to the T-bar
2
Insert the Torx security screw into the hole near the latch to lock
the AP in place.
Removing an AP Integrated Bracket from a T-Bar
1
To remove the AP from a T-bar, first remove the security screw,
then depress the latch while rotating the AP so that the T-bar
clips disengage the T-bar.
Mounting on a Truss or Pole
1
Feed the customer-supplied cable ties through the two slots on
the back of the Unleashed R500.
2
Fasten the Unleashed R500 to the truss or pole using the cable
ties.
Note:
T
his mounting bracket can also be used on a flush
drop-ceiling T-bar, so
the four rubber feet on the bottom of the
AP minimize ceiling tile displacement.
A
B
C
D
A
B
CAUTION:
Make sure that all three clasps are gripping the
T-bar!
A
B
C
B
A