Mounting on a Recessed Drop-Ceiling T-Bar

The enclosed T-bar bracket supports mounting to recessed drop ceiling 
T-bars.

Mounting an AP using the External Bracket

Removing an External Bracket from a T-Bar

Removing an External Bracket from an AP

Mounting an AP using the External Bracket

1

Insert the unit removal pin (A in 

Figure 10.

) into the hole on the 

side of the Unleashed R500 (B in 

Figure 10.

) to release the 

locking mechanism.

Figure 10. . Attaching the external bracket to the AP

2

Position the studs on the bottom of the T-bar bracket (C in 

Figure 10.

) in the mounting holes on the Unleashed R500 

enclosure, and then slide the T-bar bracket until the studs are in 
the narrow parts of the Unleashed R500 mounting keyholes 
(arrow).

3

Remove the unit removal pin (A in 

Figure 10.

) to engage the 

locking mechanism and secure the T-bar bracket to the 
Unleashed R500.

4

Make sure that the locking tab (D in 

Figure 10.

) is in the first 

position on the T-bar bracket (C in 

Figure 10.

).

5

Gently push the ceiling tiles up and out of the way.

6

Position the T-bar bracket so its two clasps grip one edge of 
the T-bar (A in 

Figure 11.

). Make sure that both clasps are 

gripping the T-bar.

Figure 11. . Attaching the external bracket to the T-bar

7

Hold the Unleashed R500 in place and gently push the locking 
tab (B in 

Figure 11.

) until its clasp grips the other edge of the T-

bar.

Removing an External Bracket from a T-Bar

1

Move the ceiling tiles out of the way.

2

Gently lift up the locking tab (A in 

Figure 12.

) by sliding your 

fingers under the tab. 

3

While lifting up on the locking tab, rotate the Unleashed R500-
and-T-bar bracket assembly (B in 

Figure 12.

). The Unleashed 

R500-and-T-bar bracket assembly comes away from the T-bar.

Figure 12. . Removing the external bracket from the T-bar

Removing an External Bracket from an AP

1

Insert the unit removal pin (A in 

Figure 13.

) into the hole on the 

side of the Unleashed R500. 

2

Gently lift up the retainer tab (B in 

Figure 13.

). 

3

Gently push the T-bar bracket (C in 

Figure 13.

) until it detaches 

from the Unleashed R500.

Figure 13. . Removing the external bracket from an AP

Mounting on a Flush Drop-Ceiling T-Bar

Mounting an AP using the Integrated Bracket

Removing an AP Integrated Bracket from a T-Bar

Mounting an AP using the Integrated Bracket

1

Orient the AP so that the T-bar is positioned between the T-bar 
clips as shown in 

Figure 14.

, then rotate the AP until the third 

T-bar clip catches the T-bar and the latch locks the T-bar in 
place (

Figure 15.

).

Figure 14. . Attaching the integrated bracket to the T-bar

Figure 15. . Locking the integrated bracket to the T-bar

2

Insert the Torx security screw into the hole near the latch to lock 
the AP in place.

Removing an AP Integrated Bracket from a T-Bar

1

To remove the AP from a T-bar, first remove the security screw, 
then depress the latch while rotating the AP so that the T-bar 
clips disengage the T-bar.

Mounting on a Truss or Pole

1

Feed the customer-supplied cable ties through the two slots on 
the back of the Unleashed R500.

2

Fasten the Unleashed R500 to the truss or pole using the cable 
ties.

Note: 

T

his mounting bracket can also be used on a flush 

drop-ceiling T-bar, so 

the four rubber feet on the bottom of the 

AP minimize ceiling tile displacement.

A

B

C

D

A

B

CAUTION: 

Make sure that all three clasps are gripping the 

T-bar! 

A

B

C

B

A