S
TEP
6: P
OWERING
THE
AP
WITH
AC
1
Separate the AC cable connector parts by unscrewing the boot from the cable gland and the
cable gland from the connector housing.
2
Feed the end of the AC cable through the boot and cable gland.
3
Strip the AC cable as shown.
4
Insert the stripped part of the conductors into the appropriate terminals on the connector housing.
The conductors are color-coded and must be connected to the appropriate terminals as shown
Typical AC wire colors:
- (Earth Ground): Green (US), Green/Yellow (EU)
- 1 (Neutral/Return): White or Gray (US), Blue (EU)
- 2 (Line/Hot): Black (US), Brown (EU)
- 3 (not used)
NOTE:
The color coding of wire conductors varies by region. Before completing this step, check your
local wiring standards for guidance.
5
Using a small screwdriver, tighten the small screws around the connector housing to fix the
connector pins into the terminals.
6
Mate the cable gland with the connector housing, and then hand-tighten.
Two different-sized grommets are supplied in the AC connector assembly kit. Use the grommet
that is appropriate to the diameter of the AC cable that you are using.
7
Mate the boot with the cable gland, and then hand-tighten to seal.
8
Connect the AC cord connector that you have assembled to the AC power socket on the AP.
9
Connect the AC cord to an AC power source.
T
ROUBLESHOOTING
CAUTION:
If required, you can reset the AP to its factory default settings by pressing the reset button
located inside the PoE OUT/RESET port. DO NOT DO THIS UNLESS SO INSTRUCTED. (Doing this
resets the AP IP address to 192.168.0.1.)
NOTE:
After a reset, you can access the internal AP web interface using
https://192.168.0.1
.
Your device must use any other address from 192.168.0.2 through 192.168.0.254, with subnet mask
255.255.255.0 and default gateway 192.168.0.1. The username is
super
, and the password is
sp-
admin
. Refer to the ZoneFlex 7782 Dual Band 802.11n Outdoor Access Point Installation Guide and
the ZoneFlex Outdoor Access Point User Guide for information on configuring and operating the AP.
Both documents are available at
https://support.ruckuswireless.com
.
NOTE:
After an AP is removed from its mounting, it may drip some water from the channel
surrounding the radome. As long as the AP has been operating normally, this incidental water
collection and dripping is normal, and is not service-affecting.
Figure 14:
Assembling the AC power connector
36mm or 1.42in (max)
9mm or 0.35in (max)
1
3
2
Earth Ground
Neutral/Return
Line/Hot
(not used)
1
3
2
Wire Stripping Drawn
Actual Size (1:1)