background image

Copyright © 2014 Ruckus Wireless, Inc.
Published June 09 2014, Part Number 800-70553-001 Rev D

Page 4 of 4

S

TEP

 6: P

OWERING

 

THE

 AP 

WITH

 AC

1

Separate the AC cable connector parts by unscrewing the boot from the cable gland and the 
cable gland from the connector housing.

2

Feed the end of the AC cable through the boot and cable gland.

3

Strip the AC cable as shown.

4

Insert the stripped part of the conductors into the appropriate terminals on the connector housing. 
The conductors are color-coded and must be connected to the appropriate terminals as shown 

Typical AC wire colors:
- (Earth Ground): Green (US), Green/Yellow (EU)
- 1 (Neutral/Return): White or Gray (US), Blue (EU)
- 2 (Line/Hot): Black (US), Brown (EU)
- 3 (not used)

NOTE:

 

The color coding of wire conductors varies by region. Before completing this step, check your 

local wiring standards for guidance.

5

Using a small screwdriver, tighten the small screws around the connector housing to fix the 
connector pins into the terminals.

6

Mate the cable gland with the connector housing, and then hand-tighten.

Two different-sized grommets are supplied in the AC connector assembly kit. Use the grommet 
that is appropriate to the diameter of the AC cable that you are using.

7

Mate the boot with the cable gland, and then hand-tighten to seal.

8

Connect the AC cord connector that you have assembled to the AC power socket on the AP.

9

Connect the AC cord to an AC power source. 

T

ROUBLESHOOTING

CAUTION:

 

If required, you can reset the AP to its factory default settings by pressing the reset button 

located inside the PoE OUT/RESET port. DO NOT DO THIS UNLESS SO INSTRUCTED. (Doing this 
resets the AP IP address to 192.168.0.1.)

NOTE:

 

After a reset, you can access the internal AP web interface using 

https://192.168.0.1

Your device must use any other address from 192.168.0.2 through 192.168.0.254, with subnet mask 
255.255.255.0 and default gateway 192.168.0.1. The username is 

super

, and the password is 

sp-

admin

. Refer to the ZoneFlex 7782 Dual Band 802.11n Outdoor Access Point Installation Guide and 

the ZoneFlex Outdoor Access Point User Guide for information on configuring and operating the AP. 
Both documents are available at 

https://support.ruckuswireless.com

.

NOTE: 

After an AP is removed from its mounting, it may drip some water from the channel 

surrounding the radome. As long as the AP has been operating normally, this incidental water 
collection and dripping is normal, and is not service-affecting.

Figure 14:

Assembling the AC power connector

36mm or 1.42in (max)

9mm or 0.35in (max)

1

3

2

Earth Ground
Neutral/Return
Line/Hot
(not used)

1

3

2

Wire Stripping Drawn 
Actual Size (1:1)

Summary of Contents for ZoneFlex 7782

Page 1: ... 다 Veja a versão em português Brasil deste guia em https support ruckuswireless com Puede ver la versión en español América Latina de esta guía en https support ruckuswireless com PACKAGE CONTENTS Before deploying your AP in the field verify that all items listed below are included in the package If any item is damaged or missing notify your authorized Ruckus Wireless sales representative Also mak...

Page 2: ...r mount A in Figure 3 and thread the eye end through the loop end B in Figure 3 Figure 3 Hanger mount on a flat surface NOTE Hanger mount shown attached horizontally to allow AP azimuth adjustments Attach the hanger mount vertically to allow AP elevation adjustments 7 Continue with Step 3 Assembling the AP Mounting Bracket and the AP STEP 2B ATTACHING THE HANGER MOUNT TO A METAL POLE 1 Insert the ...

Page 3: ...and finger tighten until the bolt passes through the screw hole on the hanger mount Figure 10 Finger tightened hex bolt 3 Align the hole on the mounting bracket with the remaining hole on the extension bracket 4 Insert an M8 hex bolt into the hole and finger tighten until the bolt passes through the extension bracket Figure 11 Dome down mounting 5 Adjust the azimuth and elevation of the AP as requ...

Page 4: ...7 Mate the boot with the cable gland and then hand tighten to seal 8 Connect the AC cord connector that you have assembled to the AC power socket on the AP 9 Connect the AC cord to an AC power source TROUBLESHOOTING CAUTION If required you can reset the AP to its factory default settings by pressing the reset button located inside the PoE OUT RESET port DO NOT DO THIS UNLESS SO INSTRUCTED Doing th...

Reviews: