Mounting the Device
Two-Post Rack Mount Installation (ICX-RMK-4POST-TL)
Before mounting the switch in a rack, pay particular attention to the following factors:
•
Temperature: Because the temperature within a rack assembly may be higher than the ambient room temperature, check that
the rack-environment temperature is within the specified operating temperature range. (Refer to
“Environmental Considerations”
•
Mechanical loading: Do not place any equipment on top of a rack-mounted unit.
•
Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded.
•
Grounding: Rack-mounted equipment should be properly grounded. Particular attention should be given to supply connections
other than direct connections to the mains electricity supply.
To mount the product into a two-post rack using the included rack-mount kit, refer to
“Two-Post Rack Mount Installation
on page 17 for the installation procedure.
To mount the product into a four-post rack using the included rack-mount kit, refer to
“Four-Post Rack Mount Installation
on page 20 for the installation procedure.
To mount the product into a four-post rack that is between 61 cm and 81 cm (24 in. to 32 in.) deep, you can order a four-post rack kit
with the part number XBR-R000295. For the procedures to install this kit, refer to
“Installing the 1U, 1.5U, and 2U Universal Kit for
Four-Post Racks (XBR-R000295)”
Two-Post Rack Mount Installation (ICX-RMK-4POST-TL)
The Ruckus ICX 7850 can be installed in a two-post rack in various mounting positions, as shown in
.
FIGURE 7
Two-post rack mounting positions
1
Front flush mount
3
Two-post rack, side view
2
Rear mount