REMOVAL OF FAUCET: 

Alwaysturnthewatersupply

off

beforeremovingtheexistingfaucetor

disassemblingavalve.Openbothfaucethandlestorelievewater

pressureandtoensurethatthewaterhasbeensuccessfullyturnedoff.

CARE OF FAUCET: 

Theuseofwarmwaterandasoftclothisallthatisrequiredtoclean

Rubinetproducts.Thepatinaofourlivingfinishes(OilRubbedBronze&

TuscanBrass)willchangeasaresultofnormaluse.ApplyingMineralOil

onoccasionwillcreateasofterlook,subtlecolorchangesandcharacter.

WALL MOUNTED POT FILLER

MODEL8ERBHXCorL
Ifyouneedassistancewithinstallation,replacementpartsorhaveany
questionsregardingyourRubinetproduct,pleasecallaCustomer
servicerepresentativeat:

905-851-6781 

tollfree

1-800-461-5901

orvisit

www.rubinet.com

INS HX8E

8ERBHXC

8ERBHXL

BEFORE YOU BEGIN

READ ALL DIRECTIONS PRIOR TO INSTALLATION. ANY
ALTERATIONS MADE TO THE CARTRIDGES AND
FAILURE TO FOLLOW THESE INSTRUCTIONS MAY
CAUSE DAMAGE OR IMPROPER INSTALLATION WHICH
WILL NULLIFY THE WARRANTY.

• Observeandadheretoalllocalbuildingandplumbing

codes.

• Shutoffmainwatersupply.

• Finishedwallreferstotheultimatefinishedsurface,Tile,

Marbleetc.

• Itisrecommendedthatthepipesbeflushedcleanpriorto

installation,inordertoavoidproblemswithdebrislater.

• ThisPotFillerisdesignedtobeusedincloseproximityto

ordirectlyaboveastovetop.

The main consideration

therefore is what size is your largest pot and how high
off the surface of the stove top to mount the Pot Filler.

Thestandardheightofacountertopis36”astovetopis
generally2”abovethatsomounttheWallPlate16”above
thestovetopforatotalheightof54”fromthefloor.Allow
8”eithersideoftheWallPlateforthearmtoswing.

Plan

ahead!

SPECIFICATIONS

Allbrassconstruction

Twohandlewall-mounted

Adjustablequarterturnceramicdisccartridges

1/2"NPTconnections

2.2gpmflowrateat60psi