RTS Zeus User Instructions Download Page 5

SSA-424 U

SER

 M

ANUAL

 5

1

Description and
Specifications

1.1

G

ENERAL

 D

ESCRIPTION

The SSA-424 Dual Digital Hybrid intervaces two, 2-
wire intercom lines to two, 4-wire intercom lines.
Unlike earlier analog hybrids, the SSA-424 features
advanced digital signal processing to achieve
automatic nulling of the 2-wire lines.  Plus, each
hybrid features convenient peak-reading level
meters to quickly match the levels between the lines
that are being interfaced.  The result is easy and
accurate setup.  With the SSA-424, all need for test
tones, nulling adjustments and ducking adjustments
have been eliminated.

Compatible 2-wire intercom systems include RTS™
TW, Audiocom

®

, and Clear-Com

®

.  Compatible 4-

wire intercom systems include Telex’s ADAM™,
ADAM™CS, and Zeus™ Digital Matrix Intercom
Systems.

The SSA-424 is also available with optional call
signal interfacing.  This option provides bidirectional
call signal compatibility between the 2-wire and 4-
wire intercom systems.

With features like digital signal processing, peak-
reading level meters and optional call signal interfac-
ing, the SSA-424 Dual Digital Hybrid assures ease
of setup and maximum transparency between
intercom systems.

1.2 G

ENERAL

 F

EATURES

Two Independent Hybrids: Interface two separate
2-wire lines to two separate 4-wire lines.

Automatic Nulling:  Digital hybrids eliminate all
nulling and ducking adjustments.  Quick, trouble-free
setup.  Puts an end to concerns about echo and
feedback when interfacing 2-wire lines.

Peak Reading Level Meters:  Quick and accurate
visual audio level adjustment.  No extra setup equip-
ment or guesswork is required.

Direct ADAM/Zeus Audio Connection:  Accepts
standard ADAM/Zeus DB9 or RJ11 keypanel cables.

Transformer Isolated:  All audio inputs and outpus
are transformer isolated to prevent ground loops and
hum.

Call Signal Option:  Detects call signals from any of
the compatible 2-wire intercom systems, and then
provides a +5VDC output to the 4-wire intercom
system.  Accepts a contact closure input from the 4-
wire system and converts it to the call signal format
required by the 2-wire system.  The SSA-424 can be
directly connected to an ADAM, ADAM CS, or Zeus
GPI (General Purpose Interface).  GPI inputs can be
programmed to activate call signals and audio paths
to any of the available types of communication within
the 4-wire system, including intercom ports, camera
ISO circuits, IFB circuits, etc.  GPI outputs can be set
up to place calls only from a specific keypanel within
the 4-wire system, or from any keypanel within the 4-
wire system that wishes to call the 2-wire system.

Half-rack Wide, 1RU High:  Two SSA-424’s fit into a
single rack space.  Compatible with RTS TW rack
mount hardware.  Can be mixed with other TW
equipment.

Universal Power Pack:  Ready for worldwide use.
Automatically accepts any mains voltage from 100-
250 VAC, 50/60 Hz.  Power pack equipped with
locking DIN connector for attachment to the SSA-
424.

AUX

J4B

J3B

J2B

J1B

J1A

J2A

J3A

J4A

AUX

4 WIRE SYSTEM

4 WIRE SYSTEM

2 WIRE SYSTEM

Telex Communications, Inc., Made in U.S.A.

-15 -12

-9

-6

0

+3

+6

+9 +12

LEVEL

SET

SYSTEM B

-15 -12

-9

-6

-3

0

+3

+6

+9 +12

4W

2W

TO

TO

SSA-424

4W LEVEL

REF SEL

1

2

BAL

2W CHAN SEL

LEVEL

SET

SYSTEM A

-3

4W

2W

TO

TO

POWER

4W LEVEL

REF SEL

1

2

BAL

2W CHAN SEL

1

2

BAL

OFF

OFF

TM

RTN

+5V

RTN

+15V

-15V

-15V  0.3A

+15V  1.6A

+5V  3A

J5 POWER

0dB

+4dB

+8dB

+12dB

-10dB

0dB

+4dB

+8dB

+12dB

-10dB

1

2

BAL

OFF

OFF

Figure 1.  SSA-424 Reference View

Summary of Contents for Zeus

Page 1: ...WER 4W LEVEL REF SEL LEVEL SET SYSTEM A 4W 2W TO TO 2 BAL 1 1 2 BAL TW CHAN SEL 10dB 0dB 4dB 8dB 12dB 15 12 9 6 0 3 6 9 12 3 4W LEVEL REF SEL LEVEL SET SYSTEM B 4W 2W TO TO 2 BAL 1 1 2 BAL TW CHAN SEL 10dB 0dB 4dB 8dB 12dB 15 12 9 6 0 3 6 9 12 3 SSA 424 TM TM 9350 7638 000 Rev C 10 04 ...

Page 2: ...rns If a repair is necessary contact the dealer where this unit was purchased If repair through the dealer is not possible obtain a Return Authorization from Customer Service Department RTS Telex Communications Inc Phone 1 800 392 3497 Fax 1 800 323 0498 DO NOT RETURN ANY EQUIPMENT DIRECTLY TO THE FACTORY WITHOUT FIRST OBTAINING A RETURN AUTHORIZATION Be prepared to provide the company name addres...

Page 3: ...COM AUDIO CONNECTION 10 2 4 4 OTHER 2 WIRE AUDIO CONNECTION 10 2 5 4 WIRE CALL SIGNAL CONNECTIONS 11 2 5 1 CALL SIGNAL CONNECTIONS FOR ADAM ADAM CS AND ZEUS 11 2 5 2 CALL SIGNAL CONNECTIONS FOR OTHER 4 WIRE COMMUNICATON SYSTEMS 13 2 5 2 1 4 WIRE CALL SEND AND CALL ENABLE INHIBIT 13 2 5 2 2 4 WIRE CALL RECEIVE 13 2 6 2 WIRE CALL SIGNAL 14 2 6 1 CALL SIGNAL CONNECTIONS FOR AUDIOCOM RTS TW AND CLEAR ...

Page 4: ...4 SSA 424 USER MANUAL ...

Page 5: ...ired Direct ADAM Zeus Audio Connection Accepts standard ADAM Zeus DB9 or RJ11 keypanel cables Transformer Isolated All audio inputs and outpus are transformer isolated to prevent ground loops and hum Call Signal Option Detects call signals from any of the compatible 2 wire intercom systems and then provides a 5VDC output to the 4 wire intercom system Accepts a contact closure input from the 4 wire...

Page 6: ... is located at the right end of the back panel This is a locking DIN connector The remainder of the back panel is divided into connectors for the two separate hybrids Connectors are labeled with J numbers followed fy A or B to indicate system A or system B For each hybrid there is an AUX connector This is used to connect to from the optional call signal card Below the AUX connector there are both ...

Page 7: ...TIONS 2 3 1 ADAM ADAM CS OR ZEUS AUDIO CONNECTION 1 Use standard 9 pin or RJ11 keypanel cables Connect from one port of your intercom system to J2A or J3A System A connection on the back of the SSA 424 Connect from another port to J2B or J3B System B connection 2 On the SSA 424 front panel set the 4W LEVEL REF SEL switches to the 8dB posi tion 2 3 2 AUDIO CONNECTIONS FOR OTHER 4 WIRE COMMUNICATION...

Page 8: ...ations Side By Side Rack Mount Configuration Using an MCP1 Rack Mount Kit Single unit Rack Mount Configuration Using an MCP2 Rack Mount Kit Tandem Configuration Using an MCP4 Tandem Mount Kit Console Mount Configuration Using an MCP3 Console Mount Kit ...

Page 9: ...d Audiocom 1 channel cables Connect one Audiocom channel to the J1A connector on the back of the SSA 424 System A Connect a second Audiocom channelto the J1B connector System B If your Audiocom system uses 2 channel cables use a JB 2 Junction Box to split the channels Figure 4 The SSA 424 features internal DC isolation You cn therefore connect the SSA 424 to powered Audiocom cables and it will not...

Page 10: ...em A hybrid Use the J1B connector to connect a second 2 wire line to the System B hybrid The pin configuration for the J1A and J1B connectors depends on whether you are connecting a balanced or unbalanced 2 wire line Balanced Configuration Pin 1 No connection Pin 2 Balanced Audio Input Output Pin 3 Balanced Audio Input Output There are two possible configurations for unbal anced connection Unbalan...

Page 11: ...tion of the GPI outputs By default these outputs are set to duplicate the actio of the RTS FR9528 Relay Frame accessory This is the correct setting for use with the SSA 424 To check the AZedit setting select Intercom Configuration in the Options menu Click on the Options tab then verify that Configure onboard GPI outputs in FR9528 mode is selected Table 1 GPI Connector Pin out ADAM ADAM CS and Zeu...

Page 12: ...h t s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N t u p t u O I P G s r e b m u N n i P t c a t n o C y a l e R s r e b m u N n i P t c a t n o C y a l e R s r e b m u N n i P t c a t n o C y a l e R s r e b m u N n i P t c a t n o C y a l e R s r e b m u N n i P t c a t n o C y a l e R 1 6 5 2 O I U 1 ...

Page 13: ...tem if desired and the level display should provide an indication of which line is calling COMMON 4 WIRE CALL SEND CALL ENABLE INHIBIT 1 5 4 3 2 6 7 8 9 DB9F View from solder or crimp side CONNECTOR PIN NUMBERS CLEAR COM APPLICATION NOTE IF A CALL ENABLE INHIBIT SWITCH IS NOT USED A JUMPER MUST BE INSTALLED TO ENABLE CALL SIGNALING THE JUMPER IS NOT REQUIRED FOR ANY OTHER APPLICATION 10 Ohm PIN 4 ...

Page 14: ...to generate and receive a 20kHz signal superimposed on the audio as follows Balanced Audio Configuration Pin1 No connection Pin 2 Balanced 20 kHz Input Output Pin 3 Balanced 20 kHz Input Output SSA 424 Signal Specifications for balanced configu ration SSA 424 Receive 20kHz 100 Hz 100mV p p SSA 424 Send 20 kHz 800 Hz 1V p p Unbalanced Configuration 1 Pin 1 20 kHz Common Pin 2 20 kHz Input Output Pi...

Page 15: ...gnment for any key that is assigned to talk to the SSA 424 However this will cause the call lights to flash on the 2 wire line during the entire conversation Another solution is to assign a dedicated key as a UPL resource key which you could name CALL Then for each key that talks to an SSA 424 hybrid create a UPL statement that will activate assert the appropriate GPI whenever the call key AND the...

Page 16: ... s n i g e b n o i t a s r e v n o c r e t f a s d n o c e s 0 6 l i t n u e d o m x e l p u d l l u f n i s y a t S e n i l e r i w s i h T s e s a e c n o i t a s r e v n o c r e t f a s d n o c e s 0 9 f o s d o i d r e p g n i r u d t e i u q e n i l e h t p e e k o t s p l e h l a r u t a n g n i t t i m r e p e l i h w n o i t a s r e v n o c o n s i s i h T g n i k l a t e r a e l p o e p n...

Page 17: ... completes the adjustment 4 4 CALL SIGNAL OPTION CARD INSTALLATION Use these instructions to install a Call Signal Option Card in an SSA 424 that was originally ordered without it 1 Disassemble the SSA 424 as previously de scribed 2 Assemble the standoffs to the circuit board using the supplied screws and lockwashers 3 Connect the supplied power cable from J8 on the option card to J303 on the main...

Page 18: ......

Reviews: