10

Both packages require the following minimum system:

Windows® 95 with Internet Explorer 4.01 SR2
64 MB Memory
20 MB Free Hard Disk (not including swap file)
TrunkEdit: One free serial (COM) port.
TrunkSupervisor: One free serial (COM) port,

or two free serial (COM) ports if an
AutoTIMS unit is to be monitored.

NOTE

:  A minimum of two serial ports are required to

run both software packages at the same time on the
same computer.  Three serial ports are required if an
AutoTIMS unit is to be monitored by TrunkSupervisor.

TrunkEdit works with a PC attached to COM port 1 of
the TM-2000/MTM-2000 or via the TRK EDIT port of
the SWP-2000.

TrunkSupervisor works with a PC attached to COM
port 2 of the TM-2000/MTM-2000 or via the TRK
SPVR port of the SWP-2000.  See Figure 7 for an
example of how COM port 1 and 2 are labeled on the
TM-2000/MTM-2000.

Rack Mounting

Install the TM-2000(s)/MTM-2000(s), ICP-2000(s),
and SWP-2000 (if used) in the equipment rack.  The
units do not have special ventilation requirements.  If
a redundant system is being configured it is recom-
mended that the SWP-2000 be installed between the
two TM-2000(s)/MTM-2000(s).  Mount the ICP-2000
panel(s) either above of below the TM-2000(s)/MTM-
2000(s).

Trunking Connections and Setup

1.

Identify the correct wiring diagram for your

system.  For non-redundant TM-2000/MTM-2000
systems use example system in Figure 10.  For
redundant TM-2000/MTM-2000 systems use the
example in Figure 11.  Connect the trunking
system components using the appropriate wiring
diagram.  Consult the appropriate figures as
indicted in Figures 10 and 11 for specific cable
wiring diagrams.

NOTE

:  Follow the labels as placed on the TM-2000/

MTM-2000 for the specific locations of network cards
and RS-485 communication cards/port numbers.  See
Figure 8 for an example of card/port labeling.  Figure 9
depicts how the ports are mapped to the ICP-2000
panels.  Caution: On most systems Port 1 can be used
for trunking.  On special systems that use Video
Delegate Panels (VDP), Port 1 is reserved for use with
VDP panels.  Standard systems ship from the factory
without VDP support, so Port 1 is safe to use for
trunking.

2.

Interconnect one or more intercom audio ports
between the intercom systems.  These ports will
be used for trunking communication only.  Figure
10 and 11 indicate the specific cable wiring
diagrams.

Figure 7.  Serial (COM) port labels on TM-2000.

Figure 9.  ICP-2000 port mapping from TM-2000/MTM-2000

Figure 8.  TM-2000 RS-485 port and networking tables.

J1

J2

J3

J4

J5

J6

J7

J8

TELEX COMMUNICATIONS, INC.

MADE IN USA

TM

ICP-2000

J1

J2

J3

J4

J5

J6

J7

J8

TELEX COMMUNICATIONS, INC.

MADE IN USA

TM

ICP-2000

J1

J2

J3

J4

J5

J6

J7

J8

TELEX COMMUNICATIONS, INC.

MADE IN USA

TM

ICP-2000

J1

J2

J3

J4

J5

J6

J7

J8

TELEX COMMUNICATIONS, INC.

MADE IN USA

TM

ICP-2000

Ports 1-8

From TM-2000

From MTM-2000

Ports 9-16

From TM-2000

From MTM-2000

Ports 17-24

From TM-2000

From MTM-2000

Ports 25-32

From TM-2000

From MTM-2000

1

9

17

25

2

10

18

26

3

11

19

27

4

12

20

28

5

13

21

29

6

14

22

30

7

15

23

31

8

16

24

32

Summary of Contents for ICP-2000

Page 1: ...Manual Model TM 2000 Trunk Master MTM 2000 Mini Trunk Master SWP 2000 Switch Over Panel ICP 2000 Interconnect Panel Intelligent Trunking System 9350 7715 000 REV D 06 2004 TM 2000 MTM 2000 ICP 2000 SWP 2000 ...

Page 2: ...2 This page intentionally left blank ...

Page 3: ...o provide the company name address phone number a person to contact regarding the repair the type and quantity of equipment a description of the problem and the serial number s Customer Service Department Telex Communications Inc Telephone 800 392 3497 Fax 800 323 0498 Factory Service 800 553 5992 SHIPPING TO MANUFACTURER FOR REPAIR OR ADJUSTMENT All shipments of RTS products should be made via Un...

Page 4: ...4 This page intentionally left blank ...

Page 5: ...2000 Description 7 Understanding Trunking 8 Installation 8 Rack Mounting 9 Trunking Connections and Setup 9 Specifications 11 Licensing for the TM 2000 MTM 2000 12 Software Organization 12 Hardware Requirements 12 TM 2000 MTM 2000 Software Installation Configuration Options 13 Updating the TM 2000 MTM 2000 Software 13 Appendix A Useful Linux Tricks 20 ...

Page 6: ...6 This page intentionally left blank ...

Page 7: ...tch Over Panel is required Front Panel Features 1 Status indicators for power hard drive fan system temperature 2 Front security panel 3 Cooling fan 4 Power switch front 5 System reset switch 6 Status indicators from top to bottom Power Hard Disk Fan Failure Over Tem perature 1 Over Temperature 2 7 Floppy drive 8 System over temperature alarm silence switch 9 CD ROM drive Used only for factory ser...

Page 8: ...for TrunkEdit and TrunkSupervisor software packages via serial connections to a Windows based PC status moni toring of both TM 2000 MTM 2000 units and control of both TM 2000 MTM 2000 units when used in a redundant configuration Front Panel Features 1 Power LED Indicates that the SWP 2000 has power 2 TM MTM A Status LEDs Indications for Activity Active TM MTM Standby TM MTM Other TM MTM The Activi...

Page 9: ...urposes of key assignment just as they would in their own intercom system After keys are assigned keypanel operators can activate them or talk or listen just like in their own intercom system There is no apparent difference to keypanel operators but what actually occurs in the system electronics is slightly different When a keypanel operator activates a key to talk to a destination located in anot...

Page 10: ...use the example in Figure 11 Connect the trunking system components using the appropriate wiring diagram Consult the appropriate figures as indicted in Figures 10 and 11 for specific cable wiring diagrams NOTE Follow the labels as placed on the TM 2000 MTM 2000 for the specific locations of network cards and RS 485 communication cards port numbers See Figure 8 for an example of card port labeling ...

Page 11: ...to the intercom system For further assistance with keypanel setup click the KP button on the toolbar then press the F1 key on the computer keyboard and select Get Help on Keypanel Setup Also using AZedit within each intercom system select which intercom ports party lines etc will be scrollable and assignable in other intercom systems To make intercom ports scrollable and assignable click the KP bu...

Page 12: ...ade flag To set or clear the Cascade flag right click on the Cas cade entry for the trunk line and select Set Cascade Flag or Clear Cascade Flag from the pop up menu that appears Repeat this procedure for each intercom system audio trunk line that will be needed When finished send the changes to the TM 2000 MTM 2000 and save the file 7 Run AZedit Within each intercom system assign keypanel keys as...

Page 13: ...necessary to log on to the TM 2000 computer to do anything from Linux Configuration of the TM 2000 MTM 2000 is done by running the TM 2000 software which automatically starts when the computer is booted Hardware Requirements Serial Ports The TM 2000 MTM 2000 requires the standard COM1 and COM2 devices COM1 used for TrunkEdit COM2 used for TrunkSupervisor One or more serial card must be installed i...

Page 14: ... may need to change if the network number is changed When installing the software it attempts to determine the hard disk drive size and partition information You have a two choices The user has control on how the hard disk is partitioned The software will generate the partitions If the default partitioning is chosen 2 partitions will be generated one at 5MB containing essential boot files and one ...

Page 15: ...15 Figure 10 Example of a non redundant TM 2000 system ...

Page 16: ...16 Figure 11 Example of a redundant TM 2000 system ...

Page 17: ...n D sub connector pinout Figure 14 50 pin SCSI type II connector pinout Figure 15 RJ 11 connector pinout Figure 16 RJ 45 Connector pinout Figure 17 DE 9S to DE 9S audio cable Figure 18 DE 9s to unspecified device audio cable Figure 19 RJ 11 to DE 9S audio cable ...

Page 18: ... RS 485 data cable Figure 23 ICP 2000 to ADAM CS RS 485 data cable Figure 24 ICP 2000 to unspecified device RS 485 data cable Figure 25 ADAM to unspecified device RS 485 data cable Figure 26 ADAM CS to unspecified device RS 485 data cable Figure 27 TM 2000 toTM 2000 network linking standard networking crossover cable ...

Page 19: ...19 Figure 28 TM 2000 to SWP 2000 parallel port status and control cable Figure 29 TM 2000 to ICP 2000 RS 485 COM ports ...

Page 20: ...or similar type with two twisted pairs with shield drain wires 4 For individual RS 232 or RS 485 data cables use Belden 8451 or similar type with single twisted pair with shield drain wire DO NOT EXCEED 50 FEET RUN LENGTH WITH RS 232 CABLES RS 232 cables can be purchased pre made from a computer dealer Use an RS 232 wired Straight Through for SWP 2000 to TM 2000 connections Use a RS 232 wired Null...

Page 21: ...ged in and doing something and need to look something up without disturbing your first session The computer can be rebooted by typing Control Alt Del You do not have to be logged in to do this Alterna tively if you are logged in as root you can type the command shutdown r0 To halt the computer rather than reboot it type the command shutdown h0 and wait for the Power down message to appear If you a...

Page 22: ......

Reviews: