  Junction Box Receiver  RCJ06 

 

 

99318  0711  D/GB 

prog.

L

N

12

µ

14

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

Model 

RCJ06-5001E-01

 

1-channel   868.30 MHz 

 

Technical Data 

Frequency: 

868.30 MHz 

Modulation: 

FSK 

Power supply: 

230 V AC / 50 Hz 

Current consumption: 

approx. 0,8 W 

Output: 

1 potential-free relay 

 

contact (SPDT) 

Max. contact rating: 

see Table of Load 

Degree of Protection: 

IP40 

Operating temperature: 

-20°C to +60°C 

Dimension: 

48 x 48 x 25 mm 

 

 

Table of Loads 

Type of Load 

 

max. load        

Resisitive Load:

 

Light bulbs, 230 V 
Halogen lamps etc. 

 

10 A / 1,380 VA 

Inductive Load: 

 

Halogen lamps with wound 
transformers 

 

  3 A / 600 VA 

(transformator at least 85% loaded) 

Non-compensated or series-  
compensated fluorescent lamps 
with ferromagnetic ballasts 

  6 A / 1,380 VA 

Parallel-compensated 
fluorescent lamps with 
ferromagnetic ballasts  

  3 A / 600 VA 

Capacity EB:

 electronic 

ballasts, electronic   
transformers etc. 

 

  6 A / 920 VA 

 

Safety Advice 

 

Carefully read through these instruc-
tions before connecting and operat-
ing the unit!

 

Caution! Electrical installation may only be 
carried out by a qualified electrician!

 

Observe the applicable laws, standards and 
regulations as well as the manufacturer’s instruc-
tions for the devices to be operated! 

Note the maximum load (see Table of Loads)!

 

Have faulty units checked by the manufacturer! 

Do not make any unauthorized alterations or 
modifications to the unit! 

The relay contact is suitable for a potential-free 
power supply in compliance with EN 60664.  

 

Intended Use 

This unit may only be used as an Easywave Junc-
tion Box Receiver together with low-powered or 
mains-powered devices! 

The manufacturer shall not be liable for any damage 
caused by improper or non-intended use! 
 
 
 

Function 

The Junction Box Receiver is designed for switching 
low-powered or mains-powered devices in the 
operating modes »ON/OFF« or »Dead Man’s 
Mode«. 

The receiver can be operated by multi-channel 
transmitters or single-channel transmitters. 
 

Using the Receiver 

 

Start-Up 

1.  Mount the receiver in accordance with the on-

site conditions. 

Note:

 The receiver fits into almost every junc-

tion box. 

2.  Connect the power supply and the device to be 

switched according to the connection diagram. 

Caution!

 Observe the applicable electrical regu-

lations! 

After connecting the receiver is in the 
operating mode. The LED is off. 

3.  Transfer the codes of the transmitters to the 

receiver (see section “Memorizing the Trans-
mission Codes“). 

Mounting Advice:

 

avoid mounting at the following 

locations, because this will affect the range: 

 

in a distribution box or housing made from metal 

 

in the immediate vicinity of large metal objects 

 

on the ground (or near it). 

 

Programming and Operating Modes 

For programming (see “Memorizing the Transmis-
sion codes (Programming)” there are 3 program-
ming modes for the 3 operating modes of the radio 
control. 

The programming modes are displayed by different 
LED flashing patterns. 

 

Prog. 
Mode 

Operating Mode 

LED Flashing 
Pattern 

ON/OFF (2-button 
operation) 

 

ON/OFF (1-button 
operation), 
Button operation  
> 1.6 seconds: OFF 

 

Dead Man’s Mode 
(Relay is triggered 
as long as the 
transmitter button is 
pressed) 

 

You can change from the operating mode to the 
programming mode 1 and from one programming 
mode to the next by briefly (< 1.6 sec.) pressing the 
programming button: Operating Mode  –> Pro-
gramming Mode 1 –> Programming Mode 2 –> 
Programming Mode 3 –> Operating Mode etc.  
 

Memorizing the Transmission Codes 
(Programming) 

In the “Memorizing the Transmission Codes” mode 
you can transfer the codes of your transmitters to 
the receiver. 

Note:

 Generally you only have to transfer the code 

of one button per transmitter channel. The code of 
the other transmitter buttons will be assigned auto-
matically. 

1.  Briefly (< 1.6 sec.) press the programming 

button. 
Programming mode 1 is activated. The LED 
flashes. If necessary change the programming 
mode (see “Programming and Operating 
Modes“). 

2.  Press and hold a transmitter channel button. As 

soon as the code has been memorized, the LED 
lights up for 4 sec. and than flashes again. Re-
lease the transmitter button. 

3.  Repeat step 2 with the other transmitters. The 

receiver can memorize up to 32 transmitter 
codes. 

 

 

4.  Briefly (< 1.6 sec.) press the programming 

button to return to the operating mode. 

Note:

 In case of longer power failure the program-

ming of the receiver remains. 
 

Deleting Specific Codes 

In the delete mode you can delete specific trans-
mission codes memorized by the receiver. 

1.  Keep the programming button pressed for more 

than 1.6 sec. The delete mode is activated. The 
LED flashes rapidly. 

2.  Press the selected transmitter channel button. If 

the code has been deleted, the LED lights up for 
4 sec. and then flashes again rapidly. 

3.  Repeat step 2 with another transmitter or briefly 

(< 1.6 sec.) press the programming button to re-
turn to the operating mode. 

 

Reset (Deleting Memory Completely) 

In the Reset mode you can delete all codes memo-
rized by the receiver. 

1.  Keep the programming button pressed for more 

than 1.6 sec. The delete mode is activated. The 
LED flashes rapidly. 

2.  Press the programming button again and keep it 

pressed for more than 1.6 sec. As soon as the 
memory has been deleted completely, the LED 
lights up for 4 sec. and then flashes again rapid-
ly. 

3.  Briefly (< 1.6 sec.) press the programming 

button to return to the operating mode. 

 

General Information 

 

Disposal 

 

Waste electrical products should not be dis-
posed of with household waste! 

Dispose of the waste product via a 
collection point for electronic scrap or 
via your specialist dealer. 

 

Put the packaging material into the 
recycling bins for cardboard, paper and 
plastics. 

 

 

Warranty 

Within the statutory warranty period we undertake to 
rectify free of charge by repair or replacement any 
product defects arising from material or production 
faults. 

Any unauthorized tampering with, or modifications 
to, the product shall render this warranty null and 
void. 
 

Conformity

 

This product complies with the essential 
requirements of the R&TTE directive 
1999/5/EG.  

 

The Declaration of Conformity can be found on the 
internet at: www.eldat.de. 
 

Customer Service 

If, despite correct handling, faults or malfunctions 
occur or if the product was damaged, please contact 
the company at the address below: 

ELDAT GmbH

 

Im Gewerbepark 14 
15711 Königs Wusterhausen 
Germany 
Phone: + 49 (0) 33 75 / 90 37-0 
Telefax: + 49 (0) 33 75 / 90 37-90 
Internet: www.eldat.de 
e-Mail: [email protected] 

Programming button with LED 

Art.-No. G66 031 08

RTS Automation Vertriebsges. Ltd.
Warschauer Str. 7
DE-03042 Cottbus
Phon: +49 355 280 9311
Mail: [email protected]
Internet: www.rts-automation-limited.de

Reviews: