Installation & Operation
70-210109-20 V1.0
Connection Options
It’s Under Control
®
PRODUCTION NOTES:
1) ALL text and lines must be Pantone White
2) Vertical white lines on both left and right sides must have a stroke weight of 0.25 points (0.003472 inches)
3) Rounded white rectangles around Relays 1-4 must have a stroke weight of 0.59 points (0.008194 inches)
MOuNTINg
The RCM-4 should be located on a secure, flat surface or mounted horizontally or vertically using the
mounting slots on either end of the RCM-4 or four mounting holes at the corners of the enclosure.
POWERINg THE RCM-4
1) AC Adapter: Connect the included power supply (12VDC/1Amp) to the power jack on the RCM-4.
or
2) Ethernet Port (Power over Ethernet): Connect a Cat-5 cable to a PoE compatible router/switch or a
PoE injector.
NOTE: The RCM-4 CANNOT be powered directly from an RTI control processor or connecting block.
uSB PORT - uPDATINg FIRMWARE/SETTINg IP ADDRESS
The RCM-4 firmware is updated via the integrated USB port using a USB-A to Micro-B cable (included).
Check the dealer section of the RTI website to see if there is a new firmware for the RCM-4.
NOTE: Setting a static IP address is unnecessary and not recommended. However, you can change IP
address settings in
Integration Designer
and download this information into the RCM-4 via the USB port.
ETHERNET - NETWORK CONNECTION
The RCM-4 Ethernet port provides communication with a 10/100 Base-T Ethernet network (LAN) for
control via an RTI XP series control processor. The port is compatible with Cat-5 cable with an RJ-45
termination (568B). The NET LINK light located on the top of the RCM-4 will be lit red when connected to
the LAN and flashes when there is network activity.
1) Connect to the Ethernet network - Connect a Cat-5 cable to the Ethernet network (LAN) and the
RCM-4 will receive an IP address from the network router via DHCP.
2) Find the MAC address of the RCM-4 - Located on the unit and on the MAC address card in the box.
3) In Integration Designer, click on the XP processor and add the RCM-4 as an expansion device.
4) Enter the MAC address of the RCM-4 into the configuration fields. This will allow the RTI system to
locate the RCM-4 on the network.
NOTE: Setting a static IP address is unnecessary and not recommended. However, you can change IP
address settings in
Integration Designer
and download this information into the RCM-4 via the USB port.
IR INPuT
The 3.5mm IR IN jack allows the RCM-4 to be controlled from many different sources, including RTI in-
wall controllers, control processors or third-party infrared repeater systems. Infrared commands trigger
open and close functions as well as adjustable hold times for momentary relay operation. The infrared
code database is available in the Integration Designer
®
programming software and the RTI website in the
dealer section. (rticorp.com)
PROgRAMMINg THE RCM-4
No direct programming of the RCM-4 is required unless the IP address configuration is adjusted (see NOTE
above).
LED STATuS
• Power LED - The Power LED will illuminate when power is supplied to the RCM-4.
• Net Link LED - The Net Link LED will illuminate if the RCM-4 is connected to an ethernet network.
• IR In LED - The IR In LED will illuminate if the RCM-4 receives an IR command.
• Relay LED - The Relay LED will illuminate red if a relay “On” command is received (contact made
between the Relay N.O. and Relay Com terminals). For a momentary “On” command, the LED will be
illuminated red for the duration of the hold time.
NOTE: The Relay LED’s will cycle on/off in sequence, when an Ethernet connection is made, but no XP
processor is found on the Ethernet network.
INTERNAL RELAY STATuS
Sending an “On” command will illuminate the Relay LED red and contact is made between the Relay N.O.
and Relay Com terminals. Sending an “Off” command will turn off the Relay LED and contact is made
between the Relay N.C. and Relay Com terminals.
RESET
ETHERNET
EXPANSION
PORT 1
PORT 2
PORT 3
PORT 4
PORT 5
PORT 6
+
+
+
+
+
+
USB
RTI COM
POWER
STATUS
RS-232
POWER / IR
+12VDC T3-24VDC SENSE RELAYS (+30VDC, 5A MAX)
IR OUTPUT LEVEL
1
2
Model
XP-6
Advanced Control Processor
Dimensions:
W: 6.8 Inches (173 mm) (Including wings)
H: 2.9 Inches (74 mm)
H: 1.2 Inches (31mm)
ZM-24 Transceiver Module
Power
Supply
RCM-4 Port Control Module
Product Contents
Contents within the box include the following items:
•
One (1) RCM-4 Relay Control Module
•
One (1) 12VDC/1A power supply
•
One (1) USB cable: USB-A to Micro-B
•
One (1) Quick reference guide
•
One (1) Card with Ethernet MAC address and serial number
RCM-4
Relay Control Module
Network Router/Switch
(PoE Class#2)
RTI Remote Control
XP-6 Control Processor
Power
Supply
Relay Controlled Devices
Tip = IR Signal
Ring = Ground
IR IN
Control the RCM-4 from
another device via infrared.
3.5mm Mono Plug
IR control from RTI in-wall
controllers, control processors
or third party infrared repeater
systems etc.
WIRINg RELAYS
The relays of the RCM-4 are Single Pole-Double Throw. This allows each relay to be wired for Normally
Open, Normally Closed, or Toggle configurations. The relays are capable of switching up to 28VDC @ 5A.
Normally Closed Wiring
Normally Open Wiring
Window Shades
Television Lift
Projection Screen
N.C.
COM
N.O.
N.C.
COM
N.O.
RELAY 1 N.O.
RELAY 1 N.O.
RELAY 1 COM
RELAY 1 COM
RELAY 1 N.C.
RELAY 1 N.C.
Relay “On”
Relay “Off”
N.C.
COM
N.O.
N.C.
COM
N.O.