MOuNTINg

The RCM-4 should be located on a secure, flat surface or mounted horizontally or vertically using the 

mounting slots on either end of the RCM-4 or four mounting holes at the corners of the enclosure. 

POWERINg THE RCM-4

1) AC Adapter: Connect the included power supply (12VDC/1Amp) to the power jack on the RCM-4. 

or

2) Ethernet Port (Power over Ethernet): Connect a Cat-5 cable to a PoE compatible router/switch or a 

PoE injector.  

NOTE: The RCM-4 CANNOT be powered directly from an RTI control processor or connecting block.

uSB PORT - uPDATINg FIRMWARE/SETTINg IP ADDRESS

The RCM-4 firmware is updated via the integrated USB port using a USB-A to Micro-B cable (included). 

Check the dealer section of the RTI website to see if there is a new firmware for the RCM-4.

NOTE: Setting a static IP address is unnecessary and not recommended.  However, you can change IP 

address settings in 

Integration Designer

 and download this information into the RCM-4 via the USB port. 

ETHERNET - NETWORK CONNECTION

The RCM-4 Ethernet port provides communication with a 10/100 Base-T Ethernet network (LAN) for 

control via an RTI XP series control processor. The port is compatible with Cat-5 cable with an RJ-45 

termination (568B). The NET LINK light located on the top of the RCM-4 will be lit red when connected to 

the LAN and flashes when there is network activity.

1) Connect to the Ethernet network - Connect a Cat-5 cable to the Ethernet network (LAN) and the 

RCM-4 will receive an IP address from the network router via DHCP.

2) Find the MAC address of the RCM-4 - Located on the unit and on the MAC address card in the box.

3) In Integration Designer, click on the XP processor and add the RCM-4 as an expansion device.

4) Enter the MAC address of the RCM-4 into the configuration fields. This will allow the RTI system to 

locate the RCM-4 on the network.

NOTE: Setting a static IP address is unnecessary and not recommended.  However, you can change IP 

address settings in 

Integration Designer

 and download this information into the RCM-4 via the USB port.

IR INPuT

The 3.5mm IR IN jack allows the RCM-4 to be controlled from many different sources, including RTI in-

wall controllers, control processors or third-party infrared repeater systems. Infrared commands trigger 

open and close functions as well as adjustable hold times for momentary relay operation. The infrared 

code database is available in the Integration Designer

®

 programming software and the RTI website in the 

dealer section. (rticorp.com)

PROgRAMMINg THE RCM-4

No direct programming of the RCM-4 is required unless the IP address configuration is adjusted (see NOTE 

above). 

LED STATuS

• Power LED - The Power LED will illuminate when power is supplied to the RCM-4.

• Net Link LED - The Net Link LED will illuminate if the RCM-4 is connected to an ethernet network.

• IR In LED - The IR In LED will illuminate if the RCM-4 receives an IR command.  

• Relay LED - The Relay LED will illuminate red if a relay “On” command is received (contact made 

between the Relay N.O. and Relay Com terminals). For a momentary  “On” command, the LED will be 

illuminated red for the duration of the hold time. 

NOTE: The Relay LED’s will cycle on/off in sequence, when an Ethernet connection is made, but no XP 

processor is found on the Ethernet network. 

INTERNAL RELAY STATuS

Sending an “On” command will illuminate the Relay LED red and contact is made between the Relay N.O. 

and Relay Com terminals. Sending an “Off” command will turn off the Relay LED and contact is made     

between the Relay N.C. and Relay Com terminals.

RESET

ETHERNET

EXPANSION

PORT 1

PORT 2

PORT 3

PORT 4

PORT 5

PORT 6

+

+

+

+

+

+

USB

RTI COM

POWER

STATUS

RS-232

POWER / IR

+12VDC T3-24VDC SENSE RELAYS (+30VDC, 5A MAX)

IR OUTPUT LEVEL

1

2

Model

XP-6

Advanced Control Processor

Dimensions:

W: 6.8 Inches (173 mm) (Including wings)

H: 2.9 Inches (74 mm)

H: 1.2 Inches (31mm)

ZM-24 Transceiver Module

Power 

Supply

RCM-4 Port Control Module

Product Contents

Contents within the box include the following items:

 One (1) RCM-4 Relay Control Module

 One (1) 12VDC/1A power supply

 One (1) USB cable: USB-A to Micro-B

 One (1) Quick reference guide

 One (1) Card with Ethernet MAC address and serial number

RCM-4

Relay Control Module

Network Router/Switch

(PoE Class#2)

RTI Remote Control

XP-6 Control Processor

Power 

Supply

Relay Controlled Devices

Tip = IR Signal

Ring = Ground

IR IN

Control the RCM-4 from 

another device via infrared.

3.5mm Mono Plug

IR control from RTI in-wall 

controllers, control processors 

or third party infrared repeater 

systems etc.

WIRINg RELAYS

The relays of the RCM-4 are Single Pole-Double Throw. This allows each relay to be wired for Normally 

Open, Normally Closed, or Toggle configurations. The relays are capable of switching up to 28VDC @ 5A.

Normally Closed Wiring

Normally Open Wiring

Window Shades

Television Lift

Projection Screen

N.C.

COM

N.O.

N.C.

COM

N.O.

RELAY 1 N.O.

RELAY 1 N.O.

RELAY 1 COM

RELAY 1 COM

RELAY 1 N.C.

RELAY 1 N.C.

Relay “On”

Relay “Off”

N.C.

COM

N.O.

N.C.

COM

N.O.