background image

It’s Under Control

®

Connection Options

Ethernet

(Cat-5/6 cable)

RJ-45>DB-9 

Adapter

KX7s (Rear)

RS-232 (1)

POWER / IR

SENSE

IR / SERIAL / SENSE

EXPANSION

+12VDC, 1A

MULTI-PURPOSE I/O PORTS

RS-232 (2)

ETHERNET

RS-232 (3)

TRIGGERS

RELAYS

RTI COM

POWER

1 2 3

1 2  3

1

2

3

GND

INPUT

HIGH OUT

A B

A B A B

4

1

2

3

5

6

+12VDC

3-24VDC

12V,100mA MAX

3A@30VDC MAX

GND

GND

RS-232 Controlled Device

(Ex. Video Projector)

The following diagram shows a “control system operation” of the KX7s, which utilizes an RTI control processor (RTI XP-6s shown) and an 

RTI connecting block (RTI CB-8 shown).

CB-8 Connecting Block

XP-6s Control Processor

Mounting Wings (2) 

 

- One located on bottom of KX7s also.

Ethernet Network

Router or Switch

MOUNTING

T

he KX7s is designed for flush-mount, in-wall installations. It requires an available mounting depth of 2 inches (52.5mm) from the surface of the wall. 

IMPORTANT NOTE: There is little margin for error when fitting the KX7s into the wall opening.

Make sure to use the included cardboard cut-out template to create the correct size opening in the wall.  Additionally, carefully double-check that all 

measurements taken using the cardboard cut-out template are accurate.

MOUNTING HEIGHT

The recommended mounting height for the KX7s is between 54 inches (1.37m) and 60 inches (1.52m) from the bottom of the faceplate.

MOUNTING WINGS

Two mounting wings are located on the top and bottom of the KX7s, which can be used to secure the KX7s to drywall in retrofit installations. Place KX7s in 

the opening in the wall and tighten the mounting wing screws located on the front of the KX7s (bezel removed).

CONDUIT BOX

For new construction installations a conduit box may be purchased separately from an RTI distributor.  For mounting instructions, refer to the conduit box 

installation guide

CONNECTIONS

CONTROL PORT

      

T

he Control Port on the KX7s uses a Cat-5/6 cable with RJ-45 termination. When used in conjunction with an RTI control processor (e.g. RTI XP-6s) and 

an RTI connecting block (e.g. RTI CB-8), this port serves as the power source for the KX7s in addition to infrared and RS-485 communication.  

  

ETHERNET PORT

       

The KX7s is designed for connection to a LAN via Cat-5/6 cabling with RJ-45 termination. Additionally, the KX7s can be optionally powered using Power-

Over-Ethernet, allowing the power to be extended to the KX7s over the same Cat-5/6 cable that carries Ethernet communication. When powering the 

KX7s using PoE, a class 3 PoE router or PoE injector must be used.

RS-232

      

T

he KX7s is capable of direct RS-232 communication using a Cat-5/6 cable with RJ-45 termination. A DB9 - RJ45 adaptor is included with the KX7s.      

NOTE: RS-232 communication should be limited to 50 feet (16m) depending on baud rate.

Installation & Operation

DB-9 

Pin    Signal   Signal 

 

Name   Description   

 

1  

DCD  

Carrier Detect

2  

RXD  

Receive Data

3  

TXD  

Transmit Data

4  

DTR  

Data Terminal Ready

5  

GND  

Signal Ground/Common

6  

DSR  

Data Set Ready

7  

RTS  

Request To Send

8  

CTS  

Clear To Send

9  

NC  

Not Connected

RJ-45 

 (KX7s RS-232 Output)

   

Pin    Signal   Signal 

 

Name   Description 

1  

DSR 

Data Set Ready

2  

DCD  

Carrier Detect

3  

DTR  

Data Terminal Ready

4  

GND  

Signal Ground/Common

5  

RXD  

Receive Data

6  

TXD  

Transmit Data

7  

CTS  

Clear To Send

8  

RTS  

Request To Send

DB9 - RJ45 ADAPTOR PINOUT

FERRITE RING INSTALLATION

In order to comply with regulatory agency standards for EMI 

emissions, the included ferrite ring must be installed on any cable 

attached to the KX7s Ethernet Port, Control Port, RS232 Port or 

Video Input.

• To open the ferrite ring enclosure pry open the plastic latch.

•  Insert cables into the ferrite ring at the end of the cables as 

close to the KX7s enclosure as possible.

• Close ferrite ring enclosure until the latch snaps in place.

Ferrite ring open

Ferrite ring closed - with cables

KX7s Front (Bezel removed)

PROGRAMMING

THE TOUCHSCREEN DISPLAY

The KX7s touchscreen display is programmed using the RTI Integration Designer Programming Software. Normally it is organized into a series of pages 

containing objects (buttons, text, graphics, etc.) that are related to each other. For example, they may all display information necessary for controlling a 

particular music server. 

UPDATING FIRMWARE

It is highly recommended that this and all RTI products have the latest firmware installed. The firmware can be found in the Dealer section of the RTI 

website (www.rticorp.com). Install the firmware using a USB cable (USB A to Mini B).

UPDATING SOFTWARE

R

TI’s Integration Designer data files can be downloaded to the KX7s using a USB cable (USB A to Mini B), or via hard-wired or wireless Ethernet. If the KX7s 

is hard-wired to a LAN and the router has DHCP enabled, the initial data file can be made over Ethernet.

Mounting Wing Screws

Reset Button

USB Port

Ambient and Proximity Sensors

Pin 8
Pin 7
Pin 6
Pin 5
Pin 4
Pin 3
Pin 2  
Pin 1  

Ground
Ground 

Infrared 

+12 to +16 VDC
+12 to +16 VDC

Infrared

RS-485-

RS-485+

Control Port

(Cat-5/6 cable)

RS-232 Port

 (Cat-5/6 cable)

Control Port

(Pinout)

Reviews: