4. The setting of DIP switches and operating parameters
The setting of current Standby current The setting of pulse per revolution Filtering Pulse mode
4.1 The setting of current
Sine peak A
SW1
SW2
SW3
Remarks
2.3
on
on
on
User can set 8 levels of
current through debugging
software
3.0
off
on
on
3.7
on
off
on
4.4
off
off
on
5.1
on
on
off
5.8
off
on
off
6.5
on
off
off
7.2
off
off
off
4.2 Standby current
SW4 is used to set the current percentage of the driver when it is in standby.
SW4 = ON, as long as the driver is in the enabled state, the current remains at the set current
SW4 = OFF. After the driver stops receiving pulses for a certain time, it enters the standby state,
and the current drops to a certain percentage of the set current.
The default setting is: 1 second after stopping receiving the pulse, the motor winding current will be
50%.
4.3 The setting of pulse per revolution
Set the pulse per revolution required by the motor. Due to digital control, the number of subdivisions
can be set to any number between 200 and 65535.
Steps/revolution
SW5
SW6
SW7
SW8
Remarks
7200
on
on
on
on
Users can set up 16 level
subdivision through debugging
software.
400
off
on
on
on
800
on
off
on
on
1600
off
off
on
on