11

WARNINGS

PRE-INSTALLATION AND PREPARATION SAFETY GUIDELINES

1.  Before installing this unit, check the minimum clearance to combustible section 

to ensure that the surrounding area is properly sized for the installation.

2.  The unit is for outdoor use only. DO NOT install or use this appliance inside of 

a building, garage, or any other enclosed area, including recreational vehicles 

and/or boats. This unit must be installed in such a manner that the vent opening 

at the base of the unit remains clear and free of all obstructions at all times 

during all weather conditions. 

3.  CHECK GAS TYPE (natural or propane): the gas supply you intend to use may 

not be the same as that stated on the unit rating plate as purchased. If the gas 

supply is different, convert the unit to the gas type you intend to use. See the 

CONVERTING TO A DIFFERENT GAS TYPE section. If you are unsure, contact 

the dealer for assistance. ONLY MANUAL UNITS ARE CONVERTIBLE. 

4.  FOR NATURAL GAS: The minimum inlet gas-supply pressure for purposes of 

input adjustments is 3.5” water column (w.c.), and the maximum inlet gas-supply 

pressure is 10.5” w.c. FOR PROPANE: The minimum inlet gas supply pressure for 

purposes of input adjustment is 8” w.c., and the maximum inlet gas supply 13” 

w.c. DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF 

MAXIMUM PRESSURE IS EXCEEDED. 

5.  Gas piping system must be sized to provide inlet pressure at the maximum flow 

rate (BTU/hr). Undue pressure loss will occur if the pipe is too small, or the run is 

too long. 

6.  For installations at elevations above 2,000 ft., contact your local dealer or gas 

supplier before installing. Input ratings should be reduced approximately 4% for 

each 1,000 ft. above sea level. Refer to the national Fuel Gas Code. 

7.  The unit and its individual shutoff valve must be disconnected from the 

gas-supply piping system during any pressure testing of that system at test 

pressures in excess of ½ psi (3.5 kPa). This is accomplished by closing the gas 

supply line valve. The unit must be isolated from the gas supply piping system 

by closing its individual manual shutoff valve during any pressure testing of the 

gas-supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).

8.  INSTALLER NOTE: This unit should be installed so that it can be removed if 

service is required. 

9.  GAS-SUPPLY PLUMBING REQUIREMENTS: 

a. Apply only joint compounds that are resistant to all gases on all male pipe 

fittings. Make sure to tighten every joint securely. Do not use pipe joint 

compound to connect flare fittings. Bring the gas-supply pipe up from 

beneath the enclosure near its center (if applicable). 

Caution: Installation and maintenance must be done by an NFI Certified or other 

qualified professional installer. Installer, read these instructions before installing this 

product. Be sure you understand all safety precautions and warnings contained in this 

manual. 

Note: 

An external on/off valve in the gas line is required for safety when the unit is not in use.        

It also provides for convenient maintenance and repair. 

Summary of Contents for Milo Fire Table

Page 1: ...ou smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department WARNING Chemicals kn...

Page 2: ...1 36 x 58 Fire Table ASSEMBLY INSTRUCTIONS IMPORTANT RETAIN FOR FUTURE REFERENCE READ CAREFULLY...

Page 3: ...ART DESCRIPTION QTY A Table base 1 B Table top 1 C Burner tray 1 D Butterfly bolt M8 4 E Table glass shield 4 F Glass connector clips 4 G Glass screws 8 H 10kgs fire glass 1 I Burner lid 1 J Lock wash...

Page 4: ...LE TOP ASSEMBLY Attach the fire table top B to the base A by securing with the bolts D and the washers K J Step 2 BURNER TRAY ASSEMBLY Lower the burner tray C into the rectangular opening in the fire...

Page 5: ...ips and fasten with screws G 3 Insert another piece of glass E to the neighbor side of the clips fasten with the screws G again 4 Finally assemble the balance 2 pieces of the glasses in the same way S...

Page 6: ...p 6 PREPARE FOR LIGHTING Place a AA battery not included in the LP Valve Starter Panel before trying to ignite CAUTION Before igniting turn the valve on the LP tank Apply soap water onto all of the le...

Page 7: ...valve depressed push the igniter button to make the pilot burner fire Once the pilot burner is fired hold down the valve for over ten seconds to prevent the pilot burner flame from extinguishing then...

Page 8: ...ensure the flame is completely extinguished Push the regulator valve in and turn to the off position Allow 5 minutes of complete shut off before the appliance is reignited Step 9 COVER BURNER Use lid...

Page 9: ...the factory with an impregnating sealer that penetrates deep into the porous surface providing a long lasting barrier that locks out oils water stains and dirt Spills should be wiped up quickly to avo...

Page 10: ...ace temperatures and should stay away to avoid burns or clothing ignition 2 Young children should be carefully supervised when they are in the area of the fire pit 3 Clothing or other protective mater...

Page 11: ...pliance and immediately call your gas supplier or fire department WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance A LP cylinde...

Page 12: ...flow rate BTU hr Undue pressure loss will occur if the pipe is too small or the run is too long 6 For installations at elevations above 2 000 ft contact your local dealer or gas supplier before instal...

Page 13: ...thing or other flammable materials on or near the unit surrounding Children and adults should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or clothing igni...

Page 14: ...dard defined in no 5 above This device is commonly described as an Acme thread quick coupler 7 If the propane gas cylinder comes with a dust plug place the dust cap on the cylinder valve outlet whenev...

Page 15: ...ons Minimum Clearance to Combustible Construction NOTE NOTHING SHOULD BE ABOVE THE FIRE PIT 36 clearance between sides to any combustible construction Clearance to combustible construction Side walls...

Page 16: ...ct to accidental damage 3 Install a flare adapter not supplied to the gas supply NPT using a gas pipe sealing compound or Teflon Tape see Fig 10 3 4 Connect the flex connector to the flare adapter see...

Page 17: ...s the appliance must be isolated from the gas supply piping system by closing It s individual manual shut off valve ensuring any pressure testing of the gas supply piping system At test pressure equal...

Page 18: ...als weight 22 lbs LAVA GRANULE GLASS CRYSTAL PLACEMENT CAUTION Cuts may occur from the sharp edges on glass Use safety gloves during the placement of glass Pour the bag of lava granules or glass cryst...

Page 19: ...n fire or explosion MANUAL MATCH LIGHTING INSTRUCTIONS 1 STOP Read the safety information above 2 Lay a lighted long stem match on the surface of the decorative media near the burner ring do not hold...

Page 20: ...it while performing service work 2 Allow the unit to cool before servicing 3 The unit should be inspected regularly Excessive debris can build up on this unit from leaves dirt or other debris It is cr...

Page 21: ...ts in materials and workmanship for ONE year from the date of purchase will replace any parts or components that are found defective and not fit for the intended purpose Before assembling your fire ta...

Page 22: ...es aluminum powder coated frames that are designed to require minimum maintenance Avoid letting too much dirt build up by cleaning with mild soap and water Never leave furniture standing in water STON...

Reviews: