background image

 

7

 

Panel Descriptions

 

AC IN

 

Connect the included power cord.

Please use the cord clamp (p. 9) to fix the power cord and prevent it from being unplugged accidentally.

 

POWER LINK Cable Clamp

 

Clamp and fix the proprietary POWER LINK cable (ARC-15, sold separately). (p. 9)

 

POWER LINK Connector

 

Connect two S-OPT units using the proprietary POWER LINK cable (ARC-15, sold separately). By sharing the 
power supply, the power supply can be backed up.

 

Grounding Terminal

 

If necessary, use this terminal to connect the S-OPT chassis to an external grounding source.

 

Rear Panel

 

Never attempt to use the following sources for an external ground connection:

• Water pipes (may result in shock or electrocution).
• Gas pipes (may result in fire or explosion).
• Telephone line ground or lightning rod (may be dangerous in the event of lightning).

Summary of Contents for S-OPT

Page 1: ...allations of the RSS Digital Snake System Two S OPT units can be connected using the proprietary POWER LINK cable ARC 15 sold separately so that redundant power can be supplied from one unit to the other If power to a single unit is interrupted due to some situation or is damaged both units will still continue to operate Main Specifications Copyright 2007 ROLAND CORPORATION All rights reserved No ...

Page 2: ...has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet WARNING IMPORTANT As the colours of the wires in the mains lead of this apparatus may not correspond with the colo...

Page 3: ...ower supply cord Also the supplied power cord must not be used with any other device 009 Do not excessively twist or bend the power cord nor place heavy objects on it Doing so can damage the cord producing severed elements and short circuits Damaged cords are fire and shock hazards 011 Do not allow any objects e g flammable material coins pins or liquids of any kind water soft drinks etc to penetr...

Page 4: ... alcohol nail polish spray cans etc near the unit Swiftly wipe away any liquid that spills on the unit using a dry soft cloth 101a The unit should be located so that its location or position does not interfere with its proper venti lation 102b Always grasp only the plug on the power supply cord when plugging into or unplugging from an outlet or this unit 103a At regular intervals you should unplug...

Page 5: ...nsation may form inside the unit Damage or malfunction may result if you attempt to use the unit in this condition Therefore before using the unit you must allow it to stand for several hours until the condensation has completely evaporated 360 Depending on the material and temperature of the surface on which you place the unit its rubber feet may discolor or mar the surface You can place a piece ...

Page 6: ...REAC Port This port is used to connect REAC devices and REAC cables Connect to a REAC device using the REAC cable which comes with the S OPT a SC W100S REAC cable or a Cat5e Ethernet cable equipped with an RJ45 plug POWER Indicator EXT INT This indicator displays the power supply status When power is supplied from AC IN on the rear panel the INT LED lights blue In addition if another S OPT is conn...

Page 7: ...its using the proprietary POWER LINK cable ARC 15 sold separately By sharing the power supply the power supply can be backed up Grounding Terminal If necessary use this terminal to connect the S OPT chassis to an external grounding source Rear Panel Never attempt to use the following sources for an external ground connection Water pipes may result in shock or electrocution Gas pipes may result in ...

Page 8: ... such as a UPS Connect each AC IN of two S OPT units to a normal outlet Although both S OPT units will operate if one of the two S OPT units has power supplied to its AC IN it is recommended that power be connected and supplied to AC IN of both units to improve system reliability When there is an external backup power supply separate from the normal power supply such as UPS Connect AC IN of one S ...

Page 9: ...e power supply using the POWER LINK cable ARC 15 sold separately prevent the cable from being unplugged by fixing it using the following procedure 1 Remove the clamp screws 2 specified in the diagram and remove the POWER LINK cable clamp 2 As shown in the figure clamp the POWER LINK cable using the cable clamp and secure with the screws 2 removed in Step 1 How to Use the Power Cord Clamps Using th...

Page 10: ... the double sided adhesive tape on the rubber feet and attach the feet at the points indicated in the figure below Using the Unit While Mounted in a Rack Using the REAC Connector Cover Attaching the Rubber Feet When turning the S OPT upside down place stacks of newspapers or magazines to support the four corners or two sides so that stress is not placed on the S OPT itself Also handle the S OPT wi...

Page 11: ...ind cables tightly into bundles If you are making your own REAC cables note the following precautions in addition to those above Use plugs RJ 45 conforming to high reliability standards Do not separate the wires twisted pairs within the cables Cat5e Ethernet Cable Types There are two different types of Cat5e Ethernet cables that you can use with the REAC System Though the cables look the same on t...

Page 12: ...ilize rugged Neutrik EtherCon connectors When used with RJ45 plugs housed in EtherCon connectors this provides a robust latching connection similar to that provided by an XLR connector Neutrik offers EtherCon connectors for the fabrication of new cables models NE8MC 1 and NE8MC 1 B and EtherCon connectors that can be added to a pre made Ethernet cable models NE8MC and NE8MC B Cat5e Ethernet Cable ...

Page 13: ...rrite core on the SC 100S or the Cat5e cable near the RJ45 plug that will be connected to the REAC port Use the following procedure to install a ferrite core on an Ethernet cable 1 Lift up the ferrite core s tabs and open the ferrite core fig 6 11 eps 2 Place the REAC cable SC W100S or Ethernet cable in the ferrite core so that the core abuts the base of the cable s connector fig 6 12 eps 3 Push t...

Page 14: ...evice S OPT S OPT S 4000H 8x32 Slave REAC device 8 outputs from console 32 mic line inputs 32 mic line sources from stage 8 outputs from console Cat5e cables Cat5e cables Optical cables or optical cords in a redundant system for each Optical line in diagram ...

Page 15: ...ple S 1608 16x8 Master REAC device S 0816 8x16 Slave REAC device 8 outputs from console 16 mic line sources from stage 8 outputs from console 16 mic line inputs S OPT S OPT Cat5e cable Cat5e cable Optical cable or optical cord ...

Page 16: ...ion 10 W Dimensions 218 0 W x 239 9 D x 46 3 H mm 8 5 8 W x 9 1 2 D x 1 7 8 H inches Weight 1 3 kg 2 lbs 14 oz Operation Temperature 0 to 40 degrees centigrade 32 to 104 degrees Fahrenheit Accessories Power Cord x 1 REAC Cable 5m x 1 REAC Connector Cover x 1 Rubber Foot x 4 Screw Set x 1 Owner s Manual Options REAC Cable 100m SC W100S POWER LINK Cable ARC 15 AR LINK CABLE Rack Mount Adaptor BOSS R...

Page 17: ...For EU Countries For China ...

Page 18: ...2 4170 TAIWAN ROLAND TAIWAN ENTERPRISE CO LTD Room 5 9fl No 112 Chung Shan N Road Sec 2 Taipei TAIWAN R O C TEL 02 2561 3339 SINGAPORE MALAYSIA Roland Asia Pacific Sdn Bhd 45 1 Block C2 Jalan PJU 1 39 Dataran Prima 47301 Petaling Jaya Selangor MALAYSIA TEL 3 7805 3263 BRAZIL Roland Brasil Ltda Rua San Jose 780 Sala B Parque Industrial San Jose Cotia Sao Paulo SP BRAZIL TEL 011 4615 5666 Other CENT...

Reviews: