233
Appendix
Appendix
fig.AlgoXModDelay.eps
This is a stereo-in, stereo-out cross-modulation delay.
Delay
Cross feedback will feed back the effect sound to the opposite input (left or right).
X.MOD DELAY (Cross-modulation Delay)
Parameter (name)
Setting
Explanation
DELAY UNIT
msec, Meter, Feet,
Frame (24, 25, 29.97,
30), Note
Specifies the units for delay
MODULATION WAVE
SIN, SQR, EXP+, EXP- Waveform used for modulation
MODULATION RATE
0.1–10.0 Hz
MODULATION DEPTH
0–100
Depth of modulation
MODULATION PHASE
-180–180 deg
Phase difference between modulation L and R
L TIME
0.0–1000 ms
Time from the original sound until the left-channel delay is heard
R TIME
0.0–1000 ms
Time from the original sound until the right-channel delay is heard
FB (Feedback)
-100–100
Amount of delayed sound returned to the input of the delay
XFB (Cross feedback)
-100–100
Amount of delayed sound returned to the input of the delay of the opposite
side
LO FREQ DAMP GAIN
-36.0–0.0 dB
Low-frequency attenuation of the delay sound
LO FREQ DAMP FREQ
20 Hz–2.00 kHz
Frequency at which the low-frequency region of the delay sound begins to
be attenuated
HI FREQ DAMP GAIN
-36.0–0.0 dB
High-frequency attenuation of the delay sound
HI FREQ DAMP FREQ
200 Hz–20.00 kHz
Frequency at which the high-frequency region of the delay sound begins to
be attenuated
WET POSITION
PRE DAMP
Takes the wet sound from before the damp filter
POST DAMP
Takes the wet sound from after the damp filter
WET (Wet Level)
-INF–+6.0 dB
Level of the delay sound
DRY (Dry Level)
-INF–+6.0 dB
Level of the original sound
Input L
Input R
Delay L
Output L
Output R
DRY
DRY
Delay R
XFB
FB
FB
Modulation
DPF
WET
POSITION
WET
POSITION
DPF
POST DPF
POST DPF
PRE DPF
PRE DPF
M-400_v15_e.book 233 ページ 2008年6月20日 金曜日 午後4時5分