185
REAC applications and settings
REAC applications and settings
Backup connections with the S-4000S
fig.Reac_Backup_2.eps
Set the M-400’s REAC A to master, and the S-4000S to slave. Connect
the M-400’s REAC A port to the MAIN REAC port of the S-4000S,
and connect the M-400’s SPLIT/BACKUP port to the BACKUP
REAC port of the S-4000S.
With these connections when a REAC splitter is connected between
the M-400 and the S-4000S, and a split REAC device is connected, the
split REAC device will receive the following signals.
An S-4000S in which a total of ten output modules (SO-DA4 or
SOAES4) have been installed (giving it forty output channels) can be
connected as a split REAC device, allowing the FOH console’s REAC
A port split or the SPLIT/BACKUP port output to be output as
analog audio signals (SO-DA4) or in AES/EBU format (SO-AES4).
fig.REACAES-EBU_2.eps
In this case, the S-4000S will output the following signals.
REAC INPUT 1–8
M-400 REAC A OUTPUT 1–8
REAC INPUT 9–40
S-4000S INPUT 1–32
(when you use S-4000S-3208)
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
21:
22:
23:
24:
25:
26:
27:
28:
29:
30:
31:
32:
33:
34:
35:
36:
37:
38:
39:
40:
FOH Console
OUTPUT 1–8
S-4000S
INPUT 1–32
SPLIT
/BACKUP
FOH CONSOLE
REAC A
MASTER
REAC B
MASTER
REAC SPLITER
SPLIT
REAC SPLITER
SPLIT
SLAVE
SLAVE
S-1608
BACKUP
MAIN
S-4000S-3208
Outputting the FOH split as analog
audio signals or AES/EBU
REAC INPUT 1 - 8
FOH console REAC A OUTPUT 1-8
REAC INPUT 9- 24
S-1608(A) INPUT 1 -16
REAC INPUT 25 - 40
S-1608(B) INPUT 1 - 16
SPLIT
/BACKUP
FOH CONSLE
REAC A
MASTER
REAC B
MASTER
SPLIT
SLAVE
SLAVE
S-1608(A)
S-4000S
(40 output channels)
S-1608(B)
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
15:
16:
17:
18:
19:
20:
21:
22:
23:
24:
25:
26:
27:
28:
29:
30:
31:
32:
33:
34:
35:
36:
37:
38:
39:
40:
FOH Console
OUTPUT 1–8
S-1608 (A)
INPUT 1–16
S-1608 (B)
INPUT 1–16
M-400_v15_e.book 185 ページ 2008年6月20日 金曜日 午後4時5分