38
M0720-1 ver 3.4
5 MANUAL UNLOCKING OF TOOL CHANGER
5.1 Manual unlocking
In case of failure of the control system controlling the integrated valve, the tool attachment can
be released through manual operation of the twin switches on the integrated valve.
Action
Note
1
Safety
Read the saf ety section (1.2).
2
Position tool
Place tool attachment and tool in
position f or undocking.
NOTE!
The tool attachment and tool
must be f ully supported by a tool
stand or table.
3
Pneumatic air on
Air hoses shall be saf ely connected
and the pressure in the pneumatic
system shall be on (6
–10 bar).
4
Remove cover plugs
Remove the two plugs covering the
manual control switches.
5
Release tool attachment
Press
both
manual control switches
simultaneously, with thin shaf t
screwdrivers or similar, at the rear of
the integrated valve.
WARNING!
The tool attachment will
be instantly released when both
switches are pressed!
6
Remove tool attachment
Remove tool changer f rom tool
attachment by moving the robot in
manual mode.
NOTE!
Both control switches must be
continuously pressed during
movement.
WARNING!
The tool attachment is
heavy and may cause personal injury
and equipment damage if dropped.