background image

 

 
 
 
 
 

USER MANUAL 

EVAPORATOR RS 100 PRO 

 
 
 
 

 
 
 

 

 
 
 

Summary of Contents for RS 100 PRO

Page 1: ...USER MANUAL EVAPORATOR RS 100 PRO ...

Page 2: ... Description of problem i e hardware or software Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser It shall not apply to any product or parts w...

Page 3: ...of the drive There may be electrostatic discharges between the medium and the drive which could pose a direct danger The appliance is not suitable for manual operation Safe operation is only guaranteed with the accessories described in the Accessories chapter Refer to the operating instructions for the accessories e g vacuum pump Only use the device under an all side closed exhaust or a compa rabl...

Page 4: ...resonance behaviour of the device or assembly Glass apparatus may be damaged or destroyed In the event of unbalance or unusual noises switch off the appliance immediately or reduce the speed The appliance does not start up again automatically following a cut in the power supply The device is only disconnected from the power supply network if the device power switch is off or the plug is pulled out...

Page 5: ...The package includes the following items Items Qty Main unit 1 Heating bath 1 Power cable 1 Glassware vertical 1 User Manual 1 ...

Page 6: ...working state LED power Power ON LED power flash When the unit running LED power is lit Power switch Power ON or OFF Table 2 4 2 Display Display Descriptions Remote Display in case of remote control Probe Display when using external probe Mot Display when the rotating function is switched ON Temp Display when the heating function is switched ON Timer Display when timer function is switched ON Int ...

Page 7: ...Connect the device to the power supply using power cable b Connect the heating bath to the device c Figure 7 Remove the clamping device for the angle setting of the rotation drive on the right side of the lift by rotating the knurled screw d counter clockwise Set the drive at an angle of approx 30 Figure 8 Then secure the rotation drive from being accidentally turned by tightening the knurled scre...

Page 8: ... in connections Figure 9 Hold the tight fitting evaporator piston and counter clockwise e and then turn the plastic screw nut f until the evaporator piston neck Figure 9 Note Prior to commissioning hand tighten the plastic screw nut f left aligned Installing condenser seal Figure 10 and Figure 11 Figure 10 Figure 11 Installing condenser g Figure 12 and Figure 13 ...

Page 9: ...turn Tighten the cap nut hand screwed h Start the device at 200 rpm for 2 min Then tighten the cap nut firmly Figure 12 Figure 13 Installing the vertical glassware condenser locking device Figure 14 Figure 14 Connecting tubes Figure 15 Figure 15 5 2 Operation ...

Page 10: ...eck whether the fuse is broken or loose Fault in power on self test Switch OFF the unit then switch ON and reset the instruments to factory default setting If these faults are not resolved please contact manufacturer supplier 7 Maintenance and Cleaning Proper maintenance can keep instruments working properly and lengthen its lifetime Do not spray cleanser into the instrument when cleaning Unplug t...

Page 11: ...ment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 9 Specifications Items...

Reviews: