Sanitisation Guide 

NOTE:  Before  beginning  the  sanitation  process  please  ensure  that  water  is  turned off at  the  mains and  refer  to  the MSDS 
document  for  further  information.  Use  bioguard hand gel and  ensure gloves  are  worn. 

I

s

·-@?

� -

- - - -

� 

i  i 

Briefly  press cold/ ambient 
dispense  buttons to  release 
internal  water  pressure  from 
the  machine. 

Turn  on  incoming water,  allow 
service  cartridge/ doser  to  fill. 

When the  external cleaning 

(minimum 5  minutes)  is 
completed,  flush  the  machine 
using the  cold  button  with 
clean  water  until  the  dispense 

water  runs clear.  Repeat 
briefly  with  the  ambient 
button. 

Install & Operation Manual 

Remove the  existing filter. 

Dispense water  using the cold 

button  until the water  appears 
pink.  Briefly  press  the  ambient 
button  too.  Repeat with 

sparkling button  if  present. 

Turn  off water  and  remove  the 
service filter.  Retain  service 
filter  for reuse. 

12 

Add  25  ml  of  Bioguard 

Internal  Sanitisation  fluid to  a 

clean  and  empty  service  filter 
cartridge. 

Leave the solution  inside 

machine  for  sanitisation 

to  take effect  (minimum 5 
minutes)  while  thoroughly 
cleaning the  machine 
externally,  pay  particular 
attention  to  the dispense 
faucet and button  controls. 

Fit  new filter.  Turn  on  incoming 

water  supply. 

Connect  to  machine. 

Remember  to  include  the drip 
tray.  If  a Waste Overflow 
System  is  fitted,  empty this 
and flush  through  with  a  small 
amount  of  sanitisation  fluid if 
needed. 

Pre-flush the new  filter  to  waste 
using  the ambient button  (and 
sparkling button  if  present) 

until the water  appears 

clear  and  is free  of air.  Flush 
through  a small amount  of 
water  to  check  all  functions. 

GB 

Summary of Contents for Bag & Overstrom B4

Page 1: ...ag Overstrom B4 Sport Cleaning Guide Contact us www refreshmentsystems co uk For Service service refreshmentsystems co uk 01274 750 008 For Ingredients ingredients refreshmentsystems co uk 01226 720 482 ...

Page 2: ...Thiscleaningguideis foradviceonly Please referto theoperativemanualfor complete safetyinformationand instructionwhenconsidering any maintenanceonthe machine ...

Page 3: ...ty before carrying out any maintenance work Turn off the water supply Gl EB Gl EB ttO EB EB r 0 Co EB EB 0 0 B To drain the Direct Chill tank remove the cap on the back of the machine We recommend it is refitted immediately upon draining being completed Borg Overstrom Install Operation Manual l l Cold water drain GB ...

Page 4: ...ater appears pink Briefly press the ambient button too Repeat with sparkling button if present Turn off water and remove the service filter Retain service filter for reuse 12 Add 25 ml of Bioguard Internal Sanitisation fluid to a clean and empty service filter cartridge Leave the solution inside machine for sanitisation to take effect minimum 5 minutes while thoroughly cleaning the machine externa...

Page 5: ...ug the machine If enhanced leak Detector is fitted as optional extra locate the leak Detector valve locate the source of leakage and rectify Reset the red lever push it in If leak detector is fitted as optional extra reset the red lever push it in Borg Overstrom Install Operation Manual 13 locate the detection probe which can be found in the bottom front left hand corner Dry the probes and interna...

Page 6: ...e tank is empty of sparking water when only CO2 is being released Install Operation Manual 14 Qho Qhea ing 0 Qd il Q parlcling i Press and hold the Sparkling water dispense button until all water is expelled Ensure to release the Sparkling water button and take care to avoid releasing excess amounts of CO2 gas GB ...