Borg & Overstrom
Sanitisation Guide
NOTE: Before beginning the sanitation process please ensure that water is turned off at the mains and refer to the MSDS
document for further information. Use bioguard hand gel and ensure gloves are worn.
I
s
·-@?
� -
- - - -
�
i i
Briefly press cold/ ambient
dispense buttons to release
internal water pressure from
the machine.
Turn on incoming water, allow
service cartridge/ doser to fill.
When the external cleaning
(minimum 5 minutes) is
completed, flush the machine
using the cold button with
clean water until the dispense
water runs clear. Repeat
briefly with the ambient
button.
Install & Operation Manual
Remove the existing filter.
Dispense water using the cold
button until the water appears
pink. Briefly press the ambient
button too. Repeat with
sparkling button if present.
Turn off water and remove the
service filter. Retain service
filter for reuse.
12
Add 25 ml of Bioguard
Internal Sanitisation fluid to a
clean and empty service filter
cartridge.
Leave the solution inside
machine for sanitisation
to take effect (minimum 5
minutes) while thoroughly
cleaning the machine
externally, pay particular
attention to the dispense
faucet and button controls.
Fit new filter. Turn on incoming
water supply.
Connect to machine.
Remember to include the drip
tray. If a Waste Overflow
System is fitted, empty this
and flush through with a small
amount of sanitisation fluid if
needed.
Pre-flush the new filter to waste
using the ambient button (and
sparkling button if present)
until the water appears
clear and is free of air. Flush
through a small amount of
water to check all functions.
GB