TOPAZ Owner's Manual
19
RSF Woodburning Fireplaces
The TOPAZ is offered with many door options.
Use only genuine RSF parts. The use of any substitutes will decertify the system and may put your safety at risk.
To install the door on the fireplace, start by removing all 5 screws on the left side of the door. You can store 2 of
them as replacement screws. If the extrusions are installed, open the left extrusion. Open the hinge on the left of
the fireplace and attach the door to the hinge with 3 screws as shown in Figure 14.
Refer to the maintenance section to properly adjust the seal of the door.
LOUVER INSTALLATION
NOTE:
We recommend that you delay the
installation of the louvers until after all finishing work
is completed around the fireplace. This will reduce the
possibility of scratches, vandalism, or damage to the
finish caused by drywall dust, muriatic acid, plaster,
cement, paint or any other harmful spray or liquid.
The TOPAZ is offered with various louvers options
Use only genuine RSF parts. The use of any
substitutes will decertify the system and may put your
safety at risk.
If the extrusions are installed, open both the left and
the right extrusion. Using the 2 bolts provided, attach
the upper louver to the top of the fireplace as shown
in Figure 15. Make sure to install the upper louver
level and centered. Using the 2 very small screws
along with the 2 small lock nuts provided, attach the
bottom louver to the bottom of the fireplace as shown
in Figure 15. Again be careful to install the bottom
louver level and centered. The bottom louver is held
in the upright position by 2 magnets located on the
back side of the bottom louver.
EXTRUSION INSTALLATION
NOTE:
We recommend that you delay the
installation of the extrusions until after all finishing
work is completed around the fireplace. This will
reduce the possibility of scratches, vandalism, or
damage to the finish caused by drywall dust, muriatic
acid, plaster, cement, paint or any other harmful
spray or liquid.
Since the wall covering can be installed directly
around the fireplace without any clearance to the front
of the fireplace, the extrusions are designed to
compensate for the thickness of the wall covering that
you have installed (up to ¾“). Never encase the
extrusions with the wall covering; you need to be able
to open both the left and the right extrusions.
Once the wall covering is completely finished, take
the extrusions out of the storage bag. Using the 6
screws and the 6 washers, attach the extrusions on
the fireplace as shown in Figure 16. Tighten all
screws so that the extrusions are tight against the
wall covering and the fireplace. Make sure that both
extrusions can be opened and closed without any
difficulty using the handle at the bottom of each extrusion.
Figure 15 Louvers Installation
Figure 16 Extrusion Installation
6 screws
with washers
2 bolts
2 screws with
lock nuts