FO-HB9-2022-02
4.
Replace the floor shield
(except Delta). For the
Focus SBR, Opel (all versions), Focus 320, Onyx2:
the floor
shield is made of two parts. Once the internal blower is installed, the floor shield must be modified. Remove the
screw and overlap the front section with the back section. If you ever remove the blower make sure to extend
the shield again.
5.
Reinstall the magnetic bracket for the bottom louver, if necessary.
6.
Replace the ash pan support, the ash pan and the ash pan plug, if necessary.
Installation of the thermal switch
Install the thermal switch, which is a heat activated switch that will turn your blower on and off as the fireplace heats
or cools.
Placement is important
. Place the thermal switch to the inner right leg or outside air box below the
firebox. Space the switch 1/8” from the fireplace bottom, the magnet will hold the thermal switch in place. If the
fireplace is equipped with an ash pan, make sure that it is still possible to remove the ash pan once the thermal
switch is installed.
Wiring for three-prong plug installation
Connect the wiring as shown below.