background image

FRONT PANEL DESCRIPTION

 

/

 

EN

EN-4

10/15/10 Version No. 00

(5)  H  Hold button: Press the   H  button to freeze or unfreeze

the display readings. In  H  mode, press the %RH / TEMP,
°C / °F, DEW or WET button to select the desired readings.

(6) %RH/TEMP button: Press the %RH/TEMP button to display

the  reading  of  %RH  and  °C  /  °F  on  the  main  display  and
secondary display alternately.

(7) Set button:

 

Enter the MX/MN mode and press the SET button to

cycle through the elapsed time and the real time of
Maximum or Minimum as displayed on the LCD.

  Press  SET  button  for  2  seconds  to  enter  the  auto-timer

datalogging setting mode, the LCD will display "

" mark.

  The  "SET"  button  is  inoperative  when  the  auto-timer

datalogging  function  is  enabled  (

  is  shown

  on  the

LCD  display).    Press  the  "

↵↵

"  enter  button  to  exit  from

the auto-timer datalogging function. The SET button will
then operate normally during the next set-up procedure.

(8) °C / °F button: Press the °C/°F button to temperature units

between Celsius (°C) and Fahrenheit (°F).

(9) MEM button: Manual data memory control key.

(10) 

↵↵

 ENTER button:

 In READ mode, press the 

↵↵

 enter button to exit READ mode.

 

In the auto-timer datalogging setting mode, press the 

↵↵

enter button to store the setting time.

 In

 

the auto-timer datalogging setting mode, press the 

↵↵

enter key to exit this mode.

Summary of Contents for RS-1365

Page 1: ...RS Stock No 712 6042 Instruction Manual RS 1365 Auto timer Datalogging Temperature Humidity Meter FR EN IT DE ES...

Page 2: ...TABLE OF CONTENTS EN 10 15 10 Version No 00 TABLE OF CONTENTS TITLE PAGE 1 SPECIFICATIONS 1 2 FRONT PANEL DESCRIPTION 3 3 MEASURING PROCEDURE 6 4 MAINTENANCE 16 5 RECALIBRATION PROCEDURE 17...

Page 3: ...er calibration Humidity 3 RH at 25 C 30 to 95 RH 5 RH at 25 C 10 to 30 RH Temperature 0 5 C 0 9 F Sensor type Humidity Precision capacitance sensor Temperature Thermistor sensor Response time Humidity...

Page 4: ...ow 95 RH No condensation Storage temperature humidity 10 to 60 C below 70 RH Power supply Qty 6 x 1 5V size AAA batteries Battery life Approx 200 hours Weight 235g Dimensions 150x72x35 mm Supplied acc...

Page 5: ...9 3 6 4 7 8 5 2 1 1 Humidity temperature sensor probe 2 LCD display 3 Power button Press the button to turn the meter on or off 4 MX MN button Press the MX MN MAX MIN button to read the Maximum and Mi...

Page 6: ...or 2 seconds to enter the auto timer datalogging setting mode the LCD will display mark The SET button is inoperative when the auto timer datalogging function is enabled is shown on the LCD display Pr...

Page 7: ...et the time 13 keys In the auto timer datalogging setting mode press the or button to increase or decrease the value In READ mode press the or button to increase or decrease the displayed memory locat...

Page 8: ...rement Press the button to turn the meter on Press the C F button to select C or F unit The display will show the temperature reading C or F directly on the secondary display 3 3 Dew point temperature...

Page 9: ...nimum values displayed on the LCD When in auto timer datalogging setting mode the displayed elapsed time will be replaced by real time 4 sets of data are recorded including the main reading and subsid...

Page 10: ...ling the auto power off function Press button to turn the meter off Press and hold down the H button then press button to turn the meter on The auto power off mark will disappear from LCD to indicate...

Page 11: ...top time setting D Interval time setting The four times must be correctly set otherwise the auto timer datalogging function will not operate In auto timer datalogging setting mode press keys to select...

Page 12: ...the flicking hours digits Adjustment 1 Press the or button to set the hours to the current time 2 Press the button to change to minutes setting the minutes digits will flicker 3 Press the or buttons...

Page 13: ...hours to the desired start time 2 Press the button to change to minutes setting the minutes digits will flicker 3 Press the or buttons to set the minutes to the desired start time 4 Press the button...

Page 14: ...to set to the hours to the desired stop time 2 Press the button to change to minutes setting the minutes digits will flicker 3 Press the or buttons to set the minutes to the desired stop time 4 Press...

Page 15: ...ts Adjustment Press the or buttons to set the seconds to the desired interval time from 3 to 255 seconds Store Press the enter button to store the auto timer datalogging interval time and exit the tim...

Page 16: ...imer recording function Press the enter button to exit auto datalogging and the auto timer mark will disappear and erase the auto timer settings Download the auto timer recorded data to a PC Connect t...

Page 17: ...store one set of readings to memory The LCD will show the M mark and the memory address number Total memory size available is 99 sets When the memory is full the LCD will show the Full mark C Manual m...

Page 18: ...r to provide accurate readings Replace with Qty 6 x 1 5V AAA size batteries as follows Press the button to turn the meter off Remove the screw from the battery compartment on the rear of the instrumen...

Page 19: ...on No 00 EN 17 5 RECALIBRATION PROCEDURE The instrument should be calibrated once a year to ensure its continued accuracy Contact RS Components for further details of calibration service The address i...

Reviews: