background image

10771

Operating environment

Ambient temperature:

32°F to 122°F (0°C to 50°C)

storage temperature:

-20°C to 60°C

Ambient relative humidity:

10% to 95% (non-condensing)

Power supply (internal)

AC power connector:

IEC-type, male recessed, rear of chassis

Power input voltage:

90 to 260 Vac (auto ranging)

Power input frequency:

47-63 Hz

Power consumption:

20 watts max.

Network cable connectors 

- for the eight RJ-45 shielded female ports per hub

100Mbps: Category 5 UTP/STP

10Mbps:

Category 3, 4, 5 UTP (

Note:

Speed-sensing does not sense cable type)

Stackable cable 

- stacking may be up to four hubs, or ports 

A stacking cable with 50-pin “SCSI” male connectors, shielded, 9 inches (23cm)

long, is included with each Magnum DS8-A dual-speed add-on unit.

Switch manual

UP-LINK: MDI-X thumb-operated slide switch, converts RJ-45 port 8 from a regular
(=position) user segment port to a crossover (X position) up-link port for On/off con-
nection to a central hub or another cascaded hub. The up-link port is auto-sensing for
speed, and the up-link works the same at 10Mbps or 100Mbps.

Packaging

Enclosure:

High strength metal. Metal mounting brackets included.

Suitable for wiring closet shelf, wall or desktop mounting.

Dimensions:

9.75in. D x 8.5in. W x 1.4in. 11 (25cm x 22cm x 3.5cm)

Weight:

2.5lb. (1.15Kg)

Cooling method: Fan cooled, internal @ 9cfm

Agency approvals

UL listed (UL 1950), cUL, CE

Emissions:

Meets FCC part 15, class A

Warranty

Three years, return to factory

Federal communication commission
Radio frequency interference statement

This equipment generates, uses and can radiate frequency energy and if not installed and used
properly, that is in strict accordance with the manufacturers instruction, may cause interference
to radio communication. It has been tested and found to comply with the limits for a Class A
computing device in accordance with the specifications in Subpart J of part 15 of ECC rules,
which are designed to provide reasonable protection against such interference when operated
in a commercial environment. Operation of this equipment in a residential area is likely to
cause interference, in which case the user at his own expense will be required to take whatever
measures may be required to correct the interference.

8 Port Hub DS8-A RS

stock no. 288-5796

8 Port Hub DS8-B RS

stock no. 288-5803

Issued March 1998

10771

Dual Speed

Stackable Hubs 

Instruction Leaflet

Table of contents

1.0 Introduction __________________________________________________2

1.1 Inspecting the package and product ______________________________________2
1.2 Features and benefits ____________________________________________________2
1.3 Product description

____________________________________________________2

1.4 Stacking the hubs ______________________________________________________4
1.5 Bridge module

________________________________________________________4

1.6 Up-link switch for cascading ______________________________________________5
1.7 Applications ____________________________________________________________5

2.0 Installation ____________________________________________________7

2.1 Locating the dual-speed hubs ____________________________________________7

2.1.1 Table top or shelf mounting ________________________________________7
2.1.2  Wall (or vertical surface) mounting__________________________________7

2.2 Connecting Ethernet Media ______________________________________________7
2.3 Powering the Hubs ______________________________________________________8

3.0 Operation ____________________________________________________8

3.1 Dual-speed functionality

________________________________________________8

3.2 Auto-negotiation and speed-sensing ______________________________________9 
3.3 LED description ________________________________________________________9
3.4 Up-link switch ________________________________________________________10

4.0 Troubleshooting ______________________________________________10

4.1 Before calling for assistance ____________________________________________10
4.2 When calling for assistance______________________________________________11

5.0 Technical Specification ________________________________________11

The information provided in 

RS

technical literature is believed to be accurate and reliable; however, RS

Components assumes no responsibility for inaccuracies or omissions, or for the use of this information, and all use
of such information shall be entirely at the user’s own risk.
No responsibility is assumed by RS Components for any infringements of patents or other rights of third parties
which may result from its use.
Specifications shown in RS Components technical literature are subject to change without notice.

RS Components, PO Box 99, Corby, Northants, NN17 9RS Telephone: 01536 201234

An Electrocomponents Company

© RS Components 1997

Summary of Contents for 288-5796

Page 1: ...98 10771 Dual Speed Stackable Hubs Instruction Leaflet Table of contents 1 0 Introduction __________________________________________________2 1 1 Inspecting the package and product ___________________...

Page 2: ...nd ensure that the items list ed below are included This package should contain 1 DS8A or DS8B dual speed hub 1 AC power cord 1 Stacking cable DS8A only 1 Installation and user guide 1 2 Feature and b...

Page 3: ...the hubs operates as two hubs one hub at 10Mbps and one hub at 100Mbps in one unit Any port can connect into either the 10Mbps or the 100Mpbs traffic domain and can also change from one traffic domain...

Page 4: ...able Filter 100Mb In table Not in table None Forward 100Mb In table In table None Filter 2 Address learning address table maintenance The DS8 B bridge module is a state machine design which has a tota...

Page 5: ...domain address table 100Mb s Domain 100Mb s packets are forwarded when the destination address is IS in the 100Mb s domain address table 10Mb s Domain 10Mb s packets are forwarded when the destinatio...

Page 6: ...be used whenever possible in order to provide flexibility in a mixed speed network since dual speed ports are auto sensing for either 10 and 100Mbps 2 2 1 Connecting twisted pair RJ 45 CAT 3 or CAT 5...

Page 7: ...be used whenever possible in order to provide flexibility in a mixed speed network since dual speed ports are auto sensing for either 10 and 100Mbps 2 2 1 Connecting twisted pair RJ 45 CAT 3 or CAT 5...

Page 8: ...domain address table 100Mb s Domain 100Mb s packets are forwarded when the destination address is IS in the 100Mb s domain address table 10Mb s Domain 10Mb s packets are forwarded when the destinatio...

Page 9: ...able Filter 100Mb In table Not in table None Forward 100Mb In table In table None Filter 2 Address learning address table maintenance The DS8 B bridge module is a state machine design which has a tota...

Page 10: ...the hubs operates as two hubs one hub at 10Mbps and one hub at 100Mbps in one unit Any port can connect into either the 10Mbps or the 100Mpbs traffic domain and can also change from one traffic domain...

Page 11: ...nd ensure that the items list ed below are included This package should contain 1 DS8A or DS8B dual speed hub 1 AC power cord 1 Stacking cable DS8A only 1 Installation and user guide 1 2 Feature and b...

Page 12: ...98 10771 Dual Speed Stackable Hubs Instruction Leaflet Table of contents 1 0 Introduction __________________________________________________2 1 1 Inspecting the package and product ___________________...

Reviews: