RS Scene Automation DC1-ZW Installation Manual Download Page 2

 
 

©2007 RS Scene Automation LLC. Product specifications subject to change without notice.  DC1-

ZW • 2007.09 • #004 

 

5520 SW 159

TH

 PL SE ∙ Bellevue, WA 98006                                                

Phone: 425.644.1887 ∙ Fax: 425.644.1887 

RS

 

S

CENE 

A

UTOMATION

 

 

Z - W

A V E  

M

O T O R  

C

O N T R O L L E R

 

F

A M I L Y

 

 

http://www.rssceneautomation.com

 

[email protected]

 

DC1-ZW 

 

LED Modes

•Uncalibrated

Continuous blink every 1.5 seconds 

•Power Up

One blink upon power up

•Set to Factory Defaults

Three blinks when commanded to set factory defaults

•Z-Wave Command Received

One long blink when Z-Wave command is received

Button Functions

•Set to Factory Defaults

Press  and hold Z button, then apply power to the unit

•Perform Auto Calibration

Simultaneously press and hold OPEN and CLOSE for 5 sec

•Include / Exclude from Z-Wave Network

Briefly press Z button

•Open or Close Motor

Briefly press OPEN or CLOSE

Sensor

•Temperature Sensor Type

Aprilaire interior flush mount model 8051

•Temperature Sensor Range

32

°

F - 105

°

F; (0

°

C - 40

°

C)

•Temperature Sensor Accuracy

±

3% @ 25

°

C

•Mating Sensor Connector

2 conductor Female PTR AKZ1550/2-3.81  (18 - 24 AWG)

Electrical Specifications

•Operating Voltage

12 - 24 Volts DC

•Maximum Motor Current

10 Amps

•Fuse

10A 250V  5x20mm

•Nominal Power Consumption

< 1W with no radio activity and motor relay activated

Physical Specifications

•Dimensions (including mounting flange)

5.1 inches (length); 2.0 inches (width); 0.75 inches (height)

•Dimensions (metric, including mounting flange)

129.5mm (length); 50.8mm (width); 19mm (height)

•Enclosure Color

Bone

•Mounting Flange Hole Diameter

0.185 inches

•Mounting Flange Hole Distance

4.5 inches (114.3 mm)

•Operating Temperature Range

32

°

F - 105

°

F; (0

°

C - 40

°

C)

•Mating Power / Motor Connector

4 conductor Female PTR AKZ950/4-508-G   (12 - 18 AWG)

Agency Listings / Certifications

•FCC

VQH-DC1-ZW

•Z-Wave

Pending

S

P E C I F I C A T I O N S

 

Reviews: