The power switch light does not light up 

 

 

Check if the power switch is in the ‘on’ position (marked I). 

 

  Check if the power cord is plugged in to the AC outlet. 

 

  Check the fuse. 

 

 

The PC does not recognize the scanner 

 

  Check if the USB cable is plugged in at the scanner and the PC. 

 

  Reinstall the software. 

 

 

10.2.  REACH compliance statement  

The  European  Union  chemical  regulation  2006/1907/EEC:  REACH  (Registration, 
Evaluation, Authorization and Restriction of Chemicals), entered into force on 1

st

 June 

2007. 
 
As a manufacturer of articles (products), according to article 33, RSscan International 
NV is obligated to provide the recipient or consumer of its products, containing any of 
the  Substances  of  Very  High  Concern  (SVHC)  of  the  published  candidate  list  in  a 
concentration  above  0.1%  w/w,  with  sufficient  information  to  allow  safe  use  of  the 
product including, as a minimum, the name of that substance. 
 
All information in this statement is based on our current knowledge. We take neither 
liability nor warranty for factors beyond our knowledge and control. 
 
The majority of products supplied by RSscan International NV do not contain any of 
the  Substances  of  Very  High  Concern  (SVHC)  of  the  published  candidate  list  in  a 
concentration above 0.1% w/w. The articles listed below may contain a Substance of 
Very High Concern (SVHC) of the published candidate list in a concentration above 
this threshold. 
 

 

Article 

Substance 

CAS number 

Application 

Power cables, USB cables. 

Bis (2-ethyl(hexyl)phthalate) (DEHP) 

117-81-7 

Plasticizer in PVC cables. 

 
 

 

 

Summary of Contents for iQube E500

Page 1: ...RS PRD 00615 001 Page 1 3D Foot Scanner Model iQube E500 Installation and User Guide...

Page 2: ...mation in this guide is subject to change without notice No part of this document may be reproduced or transmitted in any way without the express written permission of RSscan International NV Register...

Page 3: ...rmation 9 2 4 Laser safety 9 2 5 Care of the 3D Foot Scanner 10 2 6 Calibration and repair 10 2 7 Limited warranty terms and conditions 10 2 8 European Union EU customer information 11 3 Unpacking and...

Page 4: ...installation and usage of the 3D Foot Scanner model iQube E500 The installation consists of Unpacking installation Software installation Connecting the scanner Starting the software Your first measure...

Page 5: ...texture This allows precise and fast scans of feet in normal ambient light conditions The laser projects a line onto the foot The camera captures the laser projection The laser and camera are mounted...

Page 6: ...anner model iQube E500 package includes iQube 3D Foot Scanner Scanner cover side support step USB cable A B 1 8m 71 Inches Do not use any other USB cable Power cord with a C13 plug the other side will...

Page 7: ...RS PRD 00615 001 Page 7 Vacuum suction cup to lift the glass plate to remove the transportation lock Unpacking instructions Optional foot switch pedal...

Page 8: ...umentation Regulatory Mark for the European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE CE mark according to the applicable European Directives Power Power off Power on USB...

Page 9: ...econds before powering up again Unplug the power cord when not in use for longer periods When unplugging the power or USB cable always pull the plug never the cable Protect the 3D Foot Scanner cables...

Page 10: ...terms and conditions The 3D Foot Scanner the Product is warranted against defects in materials and workmanship for a period of one 1 year from the date of the original purchase the Warranty Period whe...

Page 11: ...lterations or disassembly carried out by unauthorized parties Products damaged during transit to RSscan international due to insufficient or improper packaging Software refer to the End User License A...

Page 12: ...ock the clips from the scanner cover Remove the cover Unfold the support legs to transform the cover into the support step Place the support step next to the scanner for measurements in full weight be...

Page 13: ...fully installed you are ready to connect the 3D Foot Scanner Verify if the power switch is in the OFF position Marked O Connect the power cord to the 3D Foot Scanner and plug it into a properly ground...

Page 14: ...ll be performed after that the 3D Foot Scanner is ready for use The scanner button on the top will lit green when the scanner is ready 6 Start the software Refer to the Installation Guide and User Man...

Page 15: ...ransparent part of the glass to obtain the best scan result Refer to the Installation Guide and User Manual for the footscan 9 software for further instructions on how to take a measurement 8 Software...

Page 16: ...4mm 0 157 Inches Scan time 6 seconds Radiation output and standards information Laser class Max output of laser radiation Emitted wavelength s Standard s 2 lasers Class I 1 5 mW 650nm IEC 60825 1 2014...

Page 17: ...anner on or off lights red when power is on and mains connected 4 Foot pedal to connect the optional foot pedal can be used to start a measurement 5 USB connect the USB B end of the USB cable connect...

Page 18: ...umer of its products containing any of the Substances of Very High Concern SVHC of the published candidate list in a concentration above 0 1 w w with sufficient information to allow safe use of the pr...

Reviews: