Issued / Herausgegeben / Publication 11/99
V9371
743-886
General
The RS light switch offers automatic control of a wide range of lighting
loads when ambient lighting levels fall or rise above or below preset
levels.
Installation
The unit is designed to be mounted approximately 3 metres from the
ground on a vertical north wall free from shade and artificial light.
It is suitable for surface or concealed wiring connections.
1. Suitable cable - outer diameter: 9-12mm
conductor cross section
single core: 0.75-2.5mm
2
.
2. Remove front cover.
3. Insert cable grommets.
4. Insert cable.
5. Secure the rear mounting screw (max. diameter 5mm).
6. Make connections according to the wiring diagram (Fig. 1 and
Fig. 3). Insert the bared conductor until contact is made.
Note: To remove wires press down the lever with a screwdriver until
the wires can be withdrawn.
7. Replace front cover.
●
Turn slot in the direction of the notch lever.
●
Hook the cover onto the base at the back.
●
Move cover downwards towards base (the latch must click into
place).
RS
Stock No.
220....240V 10A
IN 1600W
EL 650W
N
L
A
B
C
D
min. 70mm
LED
10mm
50mm
A
B
C
D
E
1
2
Ø5.2mm
5 10
5 10
N
N
L
L
Figures / Abbildung
Twilight Switch
Dämmerungsschalter
Interrupteur a intensité variable
Instruction Leaflet
Bedienungsanleitung
Feuille d’instructions
1
2
A. Back frame
B. Screw
C. Marking
D. Latch
E. Slot
A. Sockel
B. Schraube
C. Markierung
D. Riegel
E. Schlitz
A. Cadre arrière
B. Vis
C. Repère
D. Loquet
E. Fente
A. Lever
B. Additional fixing
hole
C. Cable grommets
D. Sensor
A. Hebel
B. Zusätzliche
Montagebohrung
C. Kabeldurch-
führung
D. Sensor
A. Levier
B. Trou de fixation
supplémentaire
C. Passe-fils
D. Détecteur