RS PRO RS-8806S Instruction Manual Download Page 1

Africa

RS Components SA

P.O. Box 12182, 

Vorna Valley, 1686

20 Indianapolis Street,

Kyalami Business Park, 

Kyalami, Midrand

South Africa

www.rs-components.com

Asia

RS Components Ltd.

Suite 1601, Level 16, Tower 1,

Kowloon Commerce Centre,

51 Kwai Cheong Road,

Kwai Chung, Hong Kong

www.rs-components.com

China

RS Components Ltd.

Suite 23 A-C

East Sea Business Centre

Phase 2

No. 618 Yan'an Eastern Road

Shanghai, 200001

China

www.rs-components.com

Europe

RS Components Ltd.

PO Box 99, Corby,

Northants.

NN17 9RS 

United Kingdom

www.rs-components.com

Japan

RS Components Ltd.

West Tower (12th Floor),

Yokohama Business Park, 

134 Godocho, Hodogaya, 

Yokohama, Kanagawa 240-0005 

Japan

www.rs-components.com

U.S.A

Allied Electronics

7151 Jack Newell Blvd. S.

Fort Worth, 

Texas 76118 

U.S.A.

www.alliedelec.com

South America

RS Componentes Limitada

Av. Pdte. Eduardo Frei M. 6001-71

Centro Empresas El Cortijo

Conchali, Santiago, Chile  

www.rs-components.com

Instruction Manual

RS-8806S
Stock No:

2010210

 

Non-Contact Forehead IR Thermometer

EN

RadioShack Cat. No.

2201005

For products purchased 

through RadioShack:

General Wireless Operations Inc. 

900 Terminal Rd, Door 244

Fort Worth, Texas 76106

USA

www.radioshack.com

Summary of Contents for RS-8806S

Page 1: ...N17 9RS United Kingdom www rs components com Japan RS Components Ltd West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan www rs components com U S A Alli...

Page 2: ...se the device in relative humidity higher than 85 Do not use the device near large electromagnetic fields such as found with cordless or cell phones Keep the device away from water and heat including...

Page 3: ...wer off Display Resolution 0 1 C 0 1 F Backlight LCD display Measurement Method Rectal Oral Axillary Ear Normal Temp C 36 6 to 38 35 5 to 37 5 34 7 to 37 3 35 8 to 38 Normal Temp F 97 8 to 100 4 95 9...

Page 4: ...Infrared Thermometer Precision Normal Conditions of Use Display Resolution Operating Temperature Storage Temperature Humidity Rate Power Size Weight 0 1 C 0 1 F 10 to 40 C 50 to 104 F 0 to 50 C 32 to...

Page 5: ...when inserting new batteries wait between 10 minutes for the warm up of the apparatus and when inserting the new batteries 9 3 If the device is not used for a long time once you turn it on again the d...

Page 6: ...human being For this use the Body mode Measurement range for Body mode 32 to 42 5 C 86 to 108 F You can also use the Non contact Body Infrared Thermometer to measure the temperature of an area or an o...

Page 7: ...om dust and direct sunlight 13 Troubleshooting If you happen to have one of the following problems while using the non contact forehead IR thermometer please refer to this breakdown service guide to h...

Page 8: ...etic interference Avoid using the device in high electromagnetic environment The MEDICAL DELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs to be installed and put into service ac...

Page 9: ...magnetic immunity Compliance level 3 Vrms Recommended separation distance d 1 2 p Radiated RF lEC 61000 4 3 where P is the maximum output power rating of the transmitter In watts W according to the tr...

Page 10: ...W 0 01 0 1 1 10 100 Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 0 12 0 38 1 2 3 8 12 Table 206 Recommended separation distances between portable and mobile RF commun...