KFF13T 
 

Do not site the unit close to soft fabrics, which could be sucked over the intake grill, 
blocking airflow into the unit causing it to then overheat. Allow an air gap of at least 600mm 
to the front and rear of the unit to ensure a clear airflow. 
 
To Start 
 
Connect to a suitable electrical supply. 
 
The unit cannot operate without the fan switch in the ‘1’ position. 
 
1 – Switch the fan rocker switch to ‘1’. 
2 – Switch the heater rocker switch to ‘1’. 
3 – Set the thermostat to the desired temperature. 
 
Maximum  total  ducting  length  is  7.5m  with  8”duct.  Do  not  exceed,  to run further lengths 
contact manufacturer. Keep ducting as taut and as straight as possible, avoiding kinks and 
sharp bends. Do not restrict the ducting outlet with grills. 
 
To stop 
 
Set  the  heat  rocker  switch  to  ‘0’,  fan  only  and  leave  the  unit  in  the  fan  only  mode  for  5 
minutes MINIMUM to allow the elements to cool. 
 
Once the unit’s heat has been dissipated, turn the fan rocker switch to ‘0’ and disconnect 
from the electrical supply. 
 
It is now safe to move the unit. 
 
Failure to observe these instructions could result in damage to the elements. 
 
The KFF13 is fitted with a safety limit thermostat. Should the designed operating temperature 
be  exceeded,  it  will  open  circuit  the  elements.  These  will  automatically  reset  as  the 
temperature reduces. 
 
Maximum ambient working temperature is 40°C. 
 
In  areas  where  several  heaters are used simultaneously the positioning of the units is an 
important consideration.  

 

Optional Thermostat if fitted. 

Rotating the control knob fully clockwise will cause the heater to keep providing heat until 
the ambient temperature sensed by its sensor (the copper tube located inside the rear grill) 
reaches nominally 40º C. 
 
At this point, power to the heating element will be interrupted, leaving the fan running only.  

 

If the control knob is turned anti-clockwise then the user is looking to lower the sensed 
ambient temperature at which the element switches off.  
 
When the sensed ambient temperature is below the point at which the thermostat is set to, 
power is once again applied to the element. 