Microwave Leakage Detector /
English
EN-4
2020-10-07/ V001
⚫
In order to avoid the damage caused by contamination or
static electricity, do not touch the circuit board before you
take any adequate action.
⚫
Operating Environment
-
indoors use only. The meter
was designed for being used in an environment of
pollution degree 2.
⚫
Operation Altitude: Up to 2000M.
⚫
Operating Temperature & Humidity: 5
°
C ~ 40
°
C, 0%~
80%RH.
⚫
Storage Temperature & Humidity: -10
°
C ~ 60
°
C, 0%~
70%RH.
Operation:
1.
Press
to turn the power on or off.
2.
Turn the meter on, press
to select the frequency of
2.45 GHZ or normal (50MHz to 3.5 GHz).
3.
Position the front (see Figure 1) of the meter to measure
the electromagnetic waves. Change the measurement
angle or position to obtain the highest reading value (see
Figure 2 through Figure 6).
MEASUREMENT PROCESURES:
Arrow pointing direction indicates the direction of
electromagnetic waves.
4.
The LCD displays the measured value.