RS PRO 908WHB-3 Installation And Operation Instructions Manual Download Page 5

 

 

5

For hot water installations, it is recommended to activate the pump at least 15 second every 24 hours 

in order to avoid any seizing. Select PP will activate pump protection mode. Select OO will cancel the 

function. When thermostat activating the pump, 

15

  in the display will blink. 

 

2.

 

Manual Operation 

1)

 

Anti-freezing mode 

     

You can press power button 

  to activate the anti-freezing mode. The unit only displays Clock time, 

Weekday and Room temperature. The default set temperature for anti-freezing  mode is 5

. During 

anti-freezing mode, if room temperature decrease to 5

, the unit will activate the heating system till room 

temperature reach to 9

. For hot water installations, if PP had been selected (See Configuration menu 

item 6), the unit will activate the pump at least 15 seconds every 24 hours in order to avoid any seizing. 

Press power button 

  again will terminate the anti-freezing mode and return to normal operation mode. 

2)

 

Program operation and Hold temperature operation 

Momentarily press 

 shift between program operation and hold temperature operation. 

Prog 

running 

shows when thermostat is in program operation. Thermostat controls the heating system by 

presetting program. See 

Planning your program

 section. 

Hold

 shows when thermostat is in hold 

temperature operation.

  

The thermostat will hold the room temperature at the selected setting

 

3)

 

Temperature override 

During program operation, Press   

▲、▼

  until the temperature you want is displayed. The thermostat will 

override the current programming and keep the room temperature at the selected temperature until the next 

program period begins. Then the thermostat will automatically revert to the program.

  

4)

 

Vacation Temperature hold

 

C

ontinue pressing button 

  over 3 seconds until display will show Vacation indicates you have now 

entered into vacation hold

  Use time key 

 or 

  to select the number of the days (from 1 to 99 days) 

during your vacation.

you can use 

▲、▼

to adjust the temperature during your holiday. Push button 

 

to revert to program operation.

 

5)

 

Reset operation 

If the display is abnormal, press the Reset button by using a fine probe such as a straightened paper 

clip to gently push the Rest button. This will reset the thermostat. 

 

3.

 

Set current day and time 

1)

 

Press 

    button. The display will show the hour flashing. 

2)

 

Press and hold either 

▲、▼

  until you reach the correct hour and AM/PM designation.(AM begins at 

night, PM begins at noon) 

3)

 

Press 

  button once again. The display will only show minutes flashing 

4)

 

Press and hold either 

▲、▼

  until you reach the correct minutes 

5)

 

Press 

  button once again. The display will show the day of the week flashing. 

6)

 

Press 

▲、▼

  until you reach the correct day of the week 

Press button 

  once. The display will show the correct day of the week and the time. If no keys 

are pressed within 20 seconds, the thermostat will revert to program operation. 

 

4

  Planning your program 

Look at the factory preprogrammed times and temperatures shown in the sample schedule. If this 

program will suit your needs, simply press the 

  button to begin running the factory preset program.   

Summary of Contents for 908WHB-3

Page 1: ...Separate 5 day weekday and 1 day 1 day Saturday Sunday programming with four separate time temperature periods per day z Display temperature recalibrates z Anti freezing protection z Pump protection a...

Page 2: ...erature Indicates a malfunction with the system Low battery indicator Shows when thermostat is in the programming mode Shows when thermostat is in the pump protection mode time to get up time to go ou...

Page 3: ...to the wall Place a level against bottom of base adjust until level and then tighten screws Leveling is for appearance only and will not affect thermostat operation 5 Replace control panel on the powe...

Page 4: ...18 64 35 95 Select maximum setting temperature for heating 3 03 5 5 41 20 68 Select minimum setting temperature limitation 4 04 Select temperature display to or 5 05 FA FA SL Select fast heating or s...

Page 5: ...re you want is displayed The thermostat will override the current programming and keep the room temperature at the selected temperature until the next program period begins Then the thermostat will au...

Page 6: ...he 1st heating period and the currently programmed temperature flashing icon indicates 1st program period Get up setting 2 Press to set the programmed time or programmed temperature Press once the pro...

Page 7: ...thermostat programming one final time before beginning thermostat operation 1 Press button to view the 1st weekday heating period time and temperature Each time you press button the next heating peri...

Page 8: ...8...

Reviews: