  Multi Media Cable Tester /

 

English

 

EN-10

 

2020-10-12/ V001 

 

Press            to set and exit the setting mode. 

 

Using Multiple Remote ID Locators 

The multiple remote ID locators (1 ~ 8) helps you to identify 
multiple network cable connections, as shown in Figure. 

 

 

 

 

 

The display in Figure shows that the verifier is connected to 
the cable terminated with remote ID locator number 3. 

 

 

Battery Replacement: 

The meter is powered by 9V battery x 1pc.     
Use the following procedure to replace the battery: 

1. 

Replace battery immediately when the LCD 
displays          .   

2. 

Turn the meter off and remove the battery cover. 

3. 

Replace with the new battery; take care to note the 
correct polarity. 

4. 

Re-install the battery cover. 

Summary of Contents for 2050084

Page 1: ...Instruction Manual 2050084 Multi Media Cable Tester ...

Page 2: ...2020 10 12 V001 EN 1 Contents Introduction EN 2 Features EN 2 General Specification EN 2 Instrument Description EN 3 LCD display EN 4 Safety EN 4 Operation EN 5 Battery Replacement EN 10 Limited Warranty EN 11 Contact information EN 12 ...

Page 3: ...map opens shorts miswires split pairs and remote ID numbers all on one screen Identify remote ID number on one pair only Measures distance Using multiple remote ID numbers up to 8 locations Low battery indication Auto power on off Backlit on off General specification Display LCD display Connector type RJ 45 Cable category LAN cable UTP STP Wire map test Detects opens shorts miswires split pairs Le...

Page 4: ...ith battery Accessories Manual 9V battery carrying bag CAT5 STP cable and remote ID 1 Instrument description 1 Test Enter Power 2 Setup function right key 3 Set Unit 4 Length wiremap 5 Setup function left key 6 LCD display 7 RJ 45 connector socket 8 Tripod mounting screw 9 Remote ID locator 10 RJ 45 connector socket of remote ID 11 Battery cover 12 Battery ...

Page 5: ...SETUP mode symbol 5 Result displays Pass split 6 Displays remote ID number Safety CAUTION Be extremely careful for the following conditions while measuring Do not operate the meter in any environment with explosive gas material combustible gas material steam or filled with dust In order to avoid reading incorrect data please replace the battery immediately when the symbol appears on the LCD ...

Page 6: ...ment is for indoors use only The meter was designed for being used in an environment of pollution degree 2 Operation Altitude Up to 2000M Operating Temperature Humidity 5 C 40 C 0 80 RH Storage Temperature Humidity 10 C 60 C 0 70 RH Operation 1 Connect the meter and remote ID locator to the cabling as shown in Figures 2 Press to turn the power on 3 Press k again to measures wiremap and Remote ID L...

Page 7: ... following figures show typical test results for twisted pair cabling Any error occurs will show symbol on LCD Opens Figure shows an open pair wire 4 and 5 Shorts Figure shows tow short between wires 3 4 and 5 another 1 and 8 When shorted occur the verifier maybe not show open and miswires ...

Page 8: ...ir flashes to indicate the fault LCD will show SPLIT indicate In a split pair continuity from end to end is correct but is made with wires from different pairs Split pairs cause excessive crosstalk that interferes with network operation The split pair detects of cable must be at least 5 meter 15ft in length If open short or miswired occur the split pair detects will not work 5 Press for more than ...

Page 9: ...length measurement Press or to select the tested pairs and show the length Press repeatedly to change the units of ft or m Press to exit this function Setting Mode Press for more than 2 second to enter the setting mode Press repeatedly to select the functions of auto power on off backlit on off and parameter options 0 9 ...

Page 10: ... or to select on off Press to set and exit Parameter options 0 9 Cable Types and Length In this mode press repeatedly to select the settings of 0 9 CAT5 CAT6 or UTP STP when the selected setting is flashing press or to change 0 9 CAT5 CAT6 or UTP STP Press again to select the length measurements value parameter the number is flashing press again to change the units of m or ft Press or to change th...

Page 11: ...igure The display in Figure shows that the verifier is connected to the cable terminated with remote ID locator number 3 Battery Replacement The meter is powered by 9V battery x 1pc Use the following procedure to replace the battery 1 Replace battery immediately when the LCD displays 2 Turn the meter off and remove the battery cover 3 Replace with the new battery take care to note the correct pola...

Page 12: ...dent unauthorized repair alteration contamination or abnormal conditions of operation or handling Any implied warranties arising out of the sale of this product including but not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the above RS Components shall not be liable for loss of use of the instrument or other incidental or consequential damag...

Page 13: ...ss Centre Phase 2 No 618 Yan an Eastern Road Shanghai 200001 China www rs components com Europe RS Components Ltd PO Box 99 Corby Northants NN17 9RS United Kingdom www rs components com Japan RS Components Ltd West Tower 12th Floor Yokohama Business Park 134 Godocho Hodogaya Yokohama Kanagawa 240 0005 Japan www rs components com U S A Allied Electronics 7151 Jack Newell Blvd S Fort Worth Texas 761...

Reviews: